Control Volumes and Integral Balance Laws
Learn how to choose a control volume, use the Reynolds transport theorem, and formulate and check integral balances for mass, momentum, and energy.
From Systems to Control Volumes
From systems to control volumes
A system is a fixed amount of matter that you follow as it moves. A is instead a selected region in space, bounded by a ; matter can cross that boundary. At a particular instant, the system and CV can contain the same matter. Afterward, the system follows those same particles, while the CV remains the selected region. If fluid crosses the CS, the matter inside the CV changes, so the system and CV can have different rates of change.
Choose a CV to make the balance manageable. For a tank being filled, the tank interior is a natural choice. For a nozzle, the CV can enclose the nozzle, with inlet and outlet cuts where flow properties can be estimated. State whether the CV is fixed, moving, or deforming, since its motion affects the flux calculation.
The transport theorem: storage plus transport
Let be an extensive property carried by matter and let be that property per unit mass. The is
Here is density, is fluid velocity, is the local control-surface velocity, and is the outward unit normal. The volume integral’s time derivative is accumulation inside the CV. The surface integral is net outward transport of the property.
The sign follows from the dot product. Relative motion in the outward-normal direction gives a positive contribution (outflow); motion in the inward direction gives a negative contribution (inflow). For a fixed CV, , so the transport term uses . For a moving surface, it uses fluid velocity relative to that surface, .
The theorem is a bookkeeping identity, not a physical law that tells you how a property behaves. First state the applicable system law, then use the theorem to express that law for the CV. For example, the property per unit mass is for mass, for , and for energy.
Conserving Mass
Mass conservation for a control volume
The mass of a system is constant, so its mass rate of change is zero. Apply the with and :
The first term is the rate of in the CV; the second is net outward mass flow. Thus, accumulation plus net outflow must balance to zero. This does not mean there can be no flow: mass can enter and leave while the amount inside changes or remains constant.
For a fixed CV with one inlet and one outlet, the outward-normal convention makes the outlet contribution positive and the inlet contribution negative. In mass-flow-rate notation, the balance can be written
where the inlet and outlet rates are taken as positive magnitudes. If the CV is accumulating mass, then net inflow must exceed outflow; if accumulation is zero, net inflow and outflow balance. The integral form remains the starting point, especially when there are multiple openings or a moving control surface.
Momentum and Energy Balances
Momentum: external force and momentum transport
For a system, Newton’s second law says that the net external force equals the rate of change of its momentum. Applying the transport theorem gives the control-volume form:
The right side has two distinct contributions: momentum accumulating inside the CV and momentum transported across its surface. The left side is the sum of external forces; it is not another name for momentum flux. Relevant forces can include pressure forces, viscous forces, and body forces such as weight. Pressure on a surface element contributes an inward force , with the local pressure. Include relevant pressure forces, including hydrostatic-pressure forces where applicable, on the force side of the balance. Because this equation is vector-valued, account for forces and transported momentum by direction.
Energy: heat, work, and energy carried by flow
For a system, the first law is
using the convention that heat added to the system is positive and work done by the system is positive. Define the specific total energy as
where the terms are specific internal, kinetic, and potential energy. The control-volume balance is
The right side separates energy accumulation from net energy transported through the CS. Work includes work interactions across the boundary. In common engineering forms for fixed-flow devices, pressure-flow work is combined with internal energy into enthalpy, while shaft work is written separately. State the energy and work convention being used, and use relative velocity in the flux whenever the control surface moves.
A Reliable Balance Procedure
A reliable setup for any integral balance
A consistent setup makes the mass, momentum, and energy balances easier to interpret and less prone to sign errors:
Choose and sketch the CV. Mark its boundaries, inlets, outlets, and any moving boundaries. Prefer a choice whose wall-following boundaries and inlet or outlet cuts simplify the balance.
Set conventions. Identify outward normals and coordinate directions. For momentum, establish the directions used for vector components. For energy, state pressure references and the signs for heat and work.
Identify what crosses the CS. Record the relevant velocity, density, pressure, and energy data at each opening. Identify relevant external forces for momentum and heat and work interactions for energy.
Write the full integral balance before simplifying. Keep accumulation and every inlet and outlet contribution visible. Apply the outward-normal sign convention, or use relative velocity if the CS moves.
Simplify only with justified assumptions. makes accumulation terms zero. permits constant density. Do not infer steady flow merely because the geometry is fixed.
Check signs, units, and meaning. A negative outward flux represents net inflow. Confirm that the terms have compatible units, and remember that a force balance is vector-valued.
This order keeps storage distinct from transport and prevents assumptions from hiding terms before their role is clear.
: A fixed amount of matter followed as it moves.
: The sum of specific internal, kinetic, and potential energy.