Hydrostatic Pressure and Forces
An introduction to pressure in static fluids, liquid-column measurement, and forces on submerged plane surfaces.
in a Static Fluid
in a Static Fluid
is the normal force per unit area, measured in pascals: . A fluid at rest pushes perpendicular to any surface it touches. At a point, its is the same in every direction; otherwise, the fluid would accelerate rather than remain static.
To see how changes with height, let elevation increase upward. Balancing forces on a small fluid element gives the hydrostatic relation
The negative sign means decreases as elevation rises. For constant density, integrating between a surface at and a point a depth below it gives
Thus, in a constant-density liquid under uniform gravity, rises linearly with depth and depends on the depth and density—not the container’s shape. The fluid-column contribution, , is the . If density varies, use with the density profile rather than the constant-density formula.
Absolute and
uses a perfect vacuum as its zero; uses local atmospheric as its zero. They are related by
So a gauge reading of zero does not mean there is no : it means the equals the surrounding atmosphere. For an open tank, the at depth is gauge, or absolute. This distinction matters whenever a value must be interpreted or compared: first check which reference the value uses.
Measuring with Liquid Columns
Measuring with Liquid Columns
A turns a stationary liquid-height difference into a difference. For a single liquid of density , a vertical level difference gives the magnitude
The magnitude alone does not identify which side has the higher . To determine the sign, start at a known and trace through the connected columns. In each fluid segment, moving down by a vertical distance adds , using that segment’s density; moving up subtracts it. is equal at points at the same elevation in the same continuous static fluid. In an open-tube , one side is exposed to the atmosphere, so the difference is commonly reported as . The higher applied pushes its liquid level lower.
Worked example. An open U-tube has a liquid of density and a level difference of . Using ,
This is the difference in magnitude; the lower liquid level identifies the side with greater applied .
Barometers
A uses a liquid-column height to measure atmospheric . Neglecting vapor above the column, the relation is
where is the column height. A dense liquid such as mercury allows a relatively short column. In both instruments, column height works as a measure because moving vertically through a static fluid changes according to its density and the height traversed.
Resultant Force on a Submerged Surface
Resultant Force on a Submerged Surface
acts normal to a submerged surface, but its magnitude can vary across that surface. The total force is the integral of over the area. For a plane area in a constant-density liquid, with depth , the resultant due to is
Why can the at the be used? In this setting, increases linearly with depth, so its average over a plane area equals the at the area’s . Multiplying that average by the area gives the resultant. The formula assumes constant density and gives the force due to ; if fluid acts on both sides, use the difference across the surface, so equal atmospheric pressures cancel.
The resultant acts at the , generally below the because the deeper parts experience greater . For a plane surface inclined at angle to the horizontal, its vertical depth is
where is the area’s second moment about a centroidal axis in the plane parallel to the free surface. The added term accounts for the variation across the area.
Worked example: vertical rectangular gate. A gate is wide and high, with its top at the water surface. Its area is , and its is deep. For water with , using ,
is zero gauge at the top and increases linearly to at the bottom, giving a triangular distribution. Its resultant acts two-thirds of the gate height below the surface: down, which is below the at .