Timedora

Hydrostatic Pressure and Forces

An introduction to pressure in static fluids, liquid-column measurement, and forces on submerged plane surfaces.

in a Static Fluid

in a Static Fluid

is the normal force per unit area, measured in pascals: 1 Pa=1 N/m21\,\text{Pa}=1\,\text{N/m}^2. A fluid at rest pushes perpendicular to any surface it touches. At a point, its is the same in every direction; otherwise, the fluid would accelerate rather than remain static.

To see how changes with height, let elevation zz increase upward. Balancing forces on a small fluid element gives the hydrostatic relation

dpdz=−ρg.\frac{dp}{dz}=-\rho g.

The negative sign means decreases as elevation rises. For constant density, integrating between a surface at psp_s and a point a depth hh below it gives

p=ps+ρgh.p=p_s+\rho gh.

Thus, in a constant-density liquid under uniform gravity, rises linearly with depth and depends on the depth and density—not the container’s shape. The fluid-column contribution, ρgh\rho gh, is the . If density varies, use dp/dz=−ρgdp/dz=-\rho g with the density profile rather than the constant-density formula.

Absolute and

uses a perfect vacuum as its zero; uses local atmospheric as its zero. They are related by

pabs=pg+patm.p_{\mathrm{abs}}=p_{\mathrm{g}}+p_{\mathrm{atm}}.

So a gauge reading of zero does not mean there is no : it means the equals the surrounding atmosphere. For an open tank, the at depth hh is ρgh\rho gh gauge, or patm+ρghp_{\mathrm{atm}}+\rho gh absolute. This distinction matters whenever a value must be interpreted or compared: first check which reference the value uses.

Measuring with Liquid Columns

Measuring with Liquid Columns

A turns a stationary liquid-height difference into a difference. For a single liquid of density ρm\rho_m, a vertical level difference Δh\Delta h gives the magnitude

∣Δp∣=ρmgΔh.|\Delta p|=\rho_m g\Delta h.

The magnitude alone does not identify which side has the higher . To determine the sign, start at a known and trace through the connected columns. In each fluid segment, moving down by a vertical distance Δz\Delta z adds ρgΔz\rho g\Delta z, using that segment’s density; moving up subtracts it. is equal at points at the same elevation in the same continuous static fluid. In an open-tube , one side is exposed to the atmosphere, so the difference is commonly reported as . The higher applied pushes its liquid level lower.

Worked example. An open U-tube has a liquid of density 850 kg/m3850\,\text{kg/m}^3 and a level difference of 0.12 m0.12\,\text{m}. Using g=9.81 m/s2g=9.81\,\text{m/s}^2,

∣Δp∣=(850)(9.81)(0.12)=1000.6 Pa≈1.00 kPa.|\Delta p|=(850)(9.81)(0.12)=1000.6\,\text{Pa}\approx1.00\,\text{kPa}.

This is the difference in magnitude; the lower liquid level identifies the side with greater applied .

Barometers

A uses a liquid-column height to measure atmospheric . Neglecting vapor above the column, the relation is

patm=ρmgh,p_{\mathrm{atm}}=\rho_m gh,

where hh is the column height. A dense liquid such as mercury allows a relatively short column. In both instruments, column height works as a measure because moving vertically through a static fluid changes according to its density and the height traversed.

Resultant Force on a Submerged Surface

Resultant Force on a Submerged Surface

acts normal to a submerged surface, but its magnitude can vary across that surface. The total force is the integral of over the area. For a plane area AA in a constant-density liquid, with depth hch_c, the resultant due to is

FR=∫Apg dA=ρghcA.F_R=\int_A p_g\,dA=\rho g h_c A.

Why can the at the be used? In this setting, increases linearly with depth, so its average over a plane area equals the at the area’s . Multiplying that average by the area gives the resultant. The formula assumes constant density and gives the force due to ; if fluid acts on both sides, use the difference across the surface, so equal atmospheric pressures cancel.

The resultant acts at the , generally below the because the deeper parts experience greater . For a plane surface inclined at angle θ\theta to the horizontal, its vertical depth is

hcp=hc+IGsin⁡2θAhc,h_{cp}=h_c+\frac{I_G\sin^2\theta}{A h_c},

where IGI_G is the area’s second moment about a centroidal axis in the plane parallel to the free surface. The added term accounts for the variation across the area.

Worked example: vertical rectangular gate. A gate is 2.0 m2.0\,\text{m} wide and 3.0 m3.0\,\text{m} high, with its top at the water surface. Its area is A=(2.0)(3.0)=6.0 m2A=(2.0)(3.0)=6.0\,\text{m}^2, and its is hc=1.5 mh_c=1.5\,\text{m} deep. For water with ρ=1000 kg/m3\rho=1000\,\text{kg/m}^3, using g=9.81 m/s2g=9.81\,\text{m/s}^2,

FR=(1000)(9.81)(1.5)(6.0)=88,290 N≈88.3 kN.F_R=(1000)(9.81)(1.5)(6.0)=88{,}290\,\text{N}\approx88.3\,\text{kN}.

is zero gauge at the top and increases linearly to ρg(3.0 m)\rho g(3.0\,\text{m}) at the bottom, giving a triangular distribution. Its resultant acts two-thirds of the gate height below the surface: 2.0 m2.0\,\text{m} down, which is below the at 1.5 m1.5\,\text{m}.