Minor Losses in Piping Systems
A practical introduction to the causes, calculation, and system-level accounting of minor losses in piping.
Where Come From
A physical picture of
As fluid passes through a pipe component or a change in pipe geometry, its path or speed may be disturbed. Flow separation, recirculation, and turbulence dissipate mechanical energy, producing a loss of head. The affected components include entrances, exits, bends, valves, fittings, and changes in pipe area.
The amount of loss depends on the shape of the flow path:
Entrances: A sharp-edged entrance from a large reservoir into a pipe typically has a near 0.5. Rounding or shaping the entrance reduces the loss. A re-entrant entrance generally causes more loss than a flush, sharp-edged entrance.
Exits: When a pipe discharges into a large reservoir, the pipe’s velocity head is dissipated.
Bends and elbows: Sharper turns and abrupt mitered elbows generally cause greater losses than smoother, long-radius bends.
Valves and tees: A partly closed valve usually causes more loss than the same valve fully open. A tee’s loss differs depending on whether flow continues through the run or turns into the branch.
Area changes: A sudden expansion produces a separated, mixing region; a gradual expansion usually reduces the loss. A contraction also causes loss as flow accelerates and then mixes downstream.
“Minor” describes the category of loss, not a guarantee that it is small. In a system with many fittings or short pipe runs, can make up a substantial share of total head loss. Coefficient values are indicative rather than universal: published values can vary with component geometry, size, and the velocity used to define the coefficient.
Two Ways to Represent Fitting Loss
Loss-coefficient method
A component’s head loss is commonly calculated as
where is head loss, is the dimensionless , is the reference average velocity, and is gravitational acceleration. The coefficient and velocity must be used as a pair: choose the velocity specified by the source of , often the velocity in the connected pipe. If areas differ, do not assume that every coefficient uses the same velocity.
For example, the coefficient for discharge from a pipe into a large reservoir is approximately when referenced to the pipe velocity. This is an approximate value, not a universal constant. Coefficients depend on component geometry and, in some cases, flow conditions, so use data for the actual component when available. Area changes call for coefficients or correlations specific to their geometry and velocity reference.
Equivalent-length method
A fitting can instead be represented by an of straight pipe that causes the same loss at the same flow rate. To obtain the relationship, equate the fitting-loss expression to the Darcy–Weisbach pipe-friction expression:
With the same velocity head on both sides, cancel and solve for the :
where is pipe diameter and is the . Add fitting equivalent lengths to the actual straight-pipe length, then calculate friction loss for the combined length. This is a convenient alternative to calculating each fitting loss separately, but its result depends on ; the friction factor must be consistent with the pipe and flow conditions.
Combining Losses Across a System
Add head losses in series
For components in series, add their head losses. If every coefficient uses the same pipe velocity, the minor-loss calculation can be written as one coefficient sum:
For a constant-diameter line with one entrance, two elbows, a valve, and an exit, first add the applicable coefficients for those components. Then multiply their sum by the pipe velocity head. This is the single-velocity case described above; use the coefficients appropriate to the actual components.
If pipe areas change, the velocities—and possibly the reference velocities specified for the coefficients—may differ. Calculate each component loss with its own reference velocity, then add the results:
Do not multiply a combined coefficient sum by one velocity head unless all the coefficients use that same velocity. Finally, add minor-loss head to straight-pipe friction head to obtain . That total contributes to the head a pump must supply, along with any required elevation or pressure change.
: Changes in fluid motion that dissipate mechanical energy and produce head loss.