Timedora
Free Online Flashcard Deck

2 Cabling and Physical Connectivity Free Online FlashCards

Study 2 Cabling and Physical Connectivity with 12 free online flashcards. Review key terms, definitions, and concepts with this interactive flashcard deck.

12 cards
01
Front

What commonly causes physical-layer network faults?

Back

Common causes include damaged or incorrectly terminated cables, loose or misplaced connections, faulty ports, and unsuitable cable or transceiver types.

02
Front

How should you check a network connection path?

Back

Trace the connection from the device through the wall jack and patch panel to the switch, checking that each connection reaches its intended port.

03
Front

What should you inspect when checking a cable?

Back

Look for cuts, kinks, crushing, tight bends, damaged plugs, bent or dirty contacts, and loose connections. Reseat both ends and replace visibly damaged cables.

04
Front

What does a link light tell you—and what does it not prove?

Back

A link light usually indicates that devices detect a physical connection, but LED meanings vary. No light can have several causes, and a light does not prove the cable is error-free.

05
Front

What should you check when there is no link?

Back

Check device power, cable seating, port selection and status, cable type, and every part of the path, including couplers, patch panels, media converters, and transceivers.

06
Front

How can known-good substitutions help isolate a fault?

Back

Replace the suspect cable with a known-good cable of the correct type, then try a known-good port. If the fault follows the cable, suspect it; if it stays with the port, investigate the port or device.

07
Front

What should you do when testing an in-wall cable run?

Back

Test the full run through the wall jack or patch panel, not just the short patch cords, and record the result and the location tested.

08
Front

What should you investigate for an intermittent link or poor performance?

Back

Look for damaged or stressed cable, loose terminations, or a faulty port. Check interface error counters and whether the link repeatedly drops and returns.

09
Front

What can cause an unexpected network connection?

Back

Verify that the cable is patched to the intended wall jack and switch port; connections at both ends can still lead to the wrong destination.

10
Front

What should you check when troubleshooting a fiber link fault?

Back

Confirm that the fiber type and transceivers match the equipment and intended link, and check that connectors are seated and handled according to the equipment maker’s instructions.

11
Front

What does a basic wiremap test check?

Back

A remote-unit cable tester checks whether conductors reach expected pins at the far end. A wiremap pass does not necessarily verify performance at the intended Ethernet speed.

12
Front

What does an open fault indicate on a cable test?

Back

An open means a conductor is broken or not terminated.