True or false: The listed recovery endpoint for a low-pressure appliance is 25 mm Hg absolute, regardless of the recovery equipment’s manufacture date.
3 Refrigerant Recovery Procedures Online Quiz Questions
Use this free practice quiz with 20 questions to review 3 Refrigerant Recovery Procedures, test your knowledge, and prepare for your next test or exam.
What instrument should a technician use to track the recovery cylinder’s weight during refrigerant recovery?
A technician finds that an appliance’s refrigerant is unknown and may be contaminated. What is the appropriate course of action?
- A
Mix it with the closest-known refrigerant and recover the mixture into a shared cylinder.
- B
Keep it separate and use a suitable dedicated recovery arrangement or consult a qualified service provider.
- C
Release a small amount to identify it by smell before recovery.
- D
Use any recovery unit, because the refrigerant identity does not affect equipment selection.
For a small appliance with a working compressor, what recovery percentage is generally specified when post-November 15, 1993 equipment is used?
Refrigerant that has been removed from an appliance and is described as recovered; this does not by itself show that it has been cleaned or tested.
Which statement best describes push-pull recovery?
- A
It removes all refrigerant, so no further recovery procedure is needed.
- B
It uses liquid pressure to move vapor from the appliance to the recovery cylinder.
- C
It uses vapor pressure to move bulk liquid, after which remaining refrigerant must be recovered appropriately.
- D
It is a method for cleaning refrigerant inside the appliance.
Select all actions that are appropriate when preparing a refrigerant recovery job.
- A
Check the appliance label and service information to identify the refrigerant.
- B
Use compatible recovery equipment and inspect its hoses, fittings, valves, and unit for damage.
- C
Use a cylinder with a convenient pressure rating even if it is not rated for the refrigerant.
- D
Inspect an approved cylinder, confirm its allowable fill weight, and place it on a scale.
- E
Mix different refrigerants in one cylinder if that makes the recovery setup simpler.
True or false: The evacuation levels in the stationary-appliance table are deep-vacuum targets used when preparing a system for charging.
- A
True
- B
False
A stationary medium-pressure appliance has a charge of 200 lb or more. What recovery endpoint applies when the recovery equipment was manufactured after November 15, 1993?
- A
4 in. Hg vacuum
- B
10 in. Hg vacuum
- C
15 in. Hg vacuum
- D
25 mm Hg absolute
Select all appropriate practices for managing recovered refrigerant after recovery.
- A
Keep it in a properly rated, closed, clearly identified cylinder.
- B
Combine unknown or contaminated refrigerant with a known refrigerant to simplify storage.
- C
Keep different refrigerants and unknown or contaminated refrigerant separate.
- D
Record its identity and quantity as required by workplace procedures and applicable regulations.
- E
Assume it is ready for charging because it has been removed from the appliance.
In push-pull recovery, vapor pressure moves from the appliance to the recovery cylinder. Because this method does not remove all remaining refrigerant, complete recovery with .
After recovery reaches the applicable endpoint, a technician isolates the appliance. Once pressure stabilizes, the reading is above the required endpoint. What could explain the pressure rise, and what should the technician do before opening the system?
True or false: When the equipment and setup allow it, liquid recovery can recover a large refrigerant charge more quickly.
- A
True
- B
False
A stationary medium-pressure appliance contains 150 lb of refrigerant, and the recovery equipment was manufactured after Nov. 15, 1993. What numerical evacuation endpoint, in in. Hg vacuum, applies before opening the appliance?
A stationary high-pressure appliance contains 240 lb of refrigerant. The recovery equipment was manufactured before Nov. 15, 1993. What is the listed recovery endpoint before opening the appliance?
- A
0 in. Hg vacuum
- B
4 in. Hg vacuum
- C
10 in. Hg vacuum
- D
15 in. Hg vacuum
A technician is determining the listed recovery endpoint for a very-high-pressure stationary appliance. Which statement correctly accounts for the recovery equipment’s manufacturing date?
- A
0 in. Hg vacuum for either equipment-date category
- B
4 in. Hg vacuum for either equipment-date category
- C
10 in. Hg vacuum if the equipment was manufactured after Nov. 15, 1993
- D
25 mm Hg absolute for either equipment-date category
A technician proposes using compressed air to pressure-test a refrigerant system before recovery. What should the technician do?
- A
Use oxygen briefly, then vent the system before recovery.
- B
Use compressed air only if the refrigerant is nonflammable.
- C
Use neither oxygen nor compressed air to pressurize or test the system.
- D
Use compressed air if the system pressure is too low to check for leaks.
During recovery, the unit triggers an alarm and its operating conditions are outside the manufacturer’s stated limits. What is the appropriate response?
- A
Continue recovery while monitoring only the cylinder.
- B
Stop the operation and investigate the abnormal condition.
- C
Open the appliance to relieve pressure, then restart the unit.
- D
Change valve positions until the alarm clears.
For a stationary appliance containing more than 5 lb of refrigerant, which information is needed to determine the applicable recovery endpoint in the listed requirements?
- A
Only the refrigerant type and the technician’s preferred method
- B
Only the appliance’s pressure class and whether its compressor works
- C
Only the appliance’s age and the amount of refrigerant recovered
- D
Appliance pressure class, full charge, and the relevant recovery-equipment date
The recovery-endpoint table separates high-pressure appliances into charge categories of under a specified amount and that amount or more. What is the dividing charge, in pounds?
Related study packs and tools
- Quiz
1 Routing Tables and Packet Forwarding
Practice interpreting routing-table entries and applying route selection and packet-forwarding rules, from basic route meanings to multi-step analysis.
CCNA Routing and OSPFUpdated - Quiz
2 Refrigerants and Environmental Regulations
A medium-difficulty quiz on refrigerant families, safety classifications, identification, and U.S. environmental regulations.
EPA 608 CoreUpdated - Quiz
2 Refrigeration Fundamentals and Environmental Responsibility
A medium-difficulty quiz on refrigeration-system operation, refrigerant safety, and small-appliance responsibilities.
EPA 608 Type IUpdated - Quiz
2 Static Routing Practice
Practice configuring, verifying, and troubleshooting IPv4 static routes, including route selection and administrative distance.
CCNA Routing and OSPFUpdated - Quiz
3 EPA Section 608 Type I Requirements
A medium-difficulty quiz on EPA Section 608 Type I certification scope, small-appliance criteria, and refrigerant handling requirements.
EPA 608 Type IUpdated - Quiz
3 Leak Detection, Repair, and Verification
A medium-difficulty quiz on locating refrigerant leaks, performing repairs safely, verifying system integrity, and applying relevant regulatory requirements.
EPA 608 Type IIUpdated - Quiz
3 OSPF Neighbors and Adjacencies
Assess understanding of OSPF neighbor discovery, adjacency formation, state-based troubleshooting, and interface checks.
CCNA Routing and OSPFUpdated - Quiz
4 Route Selection and Troubleshooting
A medium-difficulty quiz on route selection and troubleshooting, covering routing metrics, administrative distance, longest-prefix matching, route usability, and Cisco IOS diagnostic commands.
CCNA Routing and OSPFUpdated - Quiz
4 Spanning Tree Protocol
A medium-difficulty quiz on STP loop prevention, root and port selection, VLAN-specific operation, configuration, and troubleshooting.
CCNA VLANs and SwitchingUpdated - Quiz
5 Chiller Service Practice and Verification
Practice chiller recovery, safety checks, endpoint verification, and service documentation. Follow equipment-specific procedures and applicable requirements.
EPA 608 Type IIIUpdated - Quiz
5 Refrigerant Compliance Practice
Practice applying refrigerant compliance rules to equipment identification, refrigerant handling, technician qualifications, transfers, and recordkeeping.
EPA 608 CoreUpdated - Quiz
6 Integrated Practice and Competency Checks
A medium-difficulty quiz on safe, compliant service decisions for stationary refrigeration and air-conditioning equipment.
EPA 608 Type IIUpdated