6 Hemodynamic Monitoring Techniques Online Quiz Questions

Use this free practice quiz with 20 questions to review 6 Hemodynamic Monitoring Techniques, test your knowledge, and prepare for your next test or exam.

20 questions
01
True or false
1 point

A patient has a single central venous pressure (CVP) reading that appears elevated. Is it reliable to use that value alone to establish the patient’s intravascular volume?

  1. A

    True

  2. B

    False

02
Choose one
1 point

What does an ECG monitor display?

  1. A

    Electrical activity and heart rate

  2. B

    Cardiac output and stroke volume

  3. C

    Peripheral oxygen saturation

  4. D

    Mean arterial pressure

03
Fill in the blank
1 point

An oscillometric monitor detects cuff-pressure and uses an algorithm to estimate systolic and diastolic pressure and determine MAP.

04
Written response
1 point

Which method calculates cardiac output using oxygen consumption and the difference between arterial and mixed venous oxygen content?

05
Choose one
1 point

An arterial-pressure transducer is positioned below the reference level specified by protocol. What effect should you expect on the displayed pressure?

  1. A

    The pressure reads falsely low.

  2. B

    The pressure reads falsely low only during expiration.

  3. C

    The pressure reads falsely high.

  4. D

    The pressure is unaffected if the waveform is visible.

06
Fill in the blank
1 point

The relationship used to calculate cardiac output is CO=\text{CO} = .

07
True or false
1 point

A sudden fall in end-tidal CO₂ can accompany reduced pulmonary blood flow, but that change is specific to reduced pulmonary blood flow.

  1. A

    True

  2. B

    False

08
Written response
1 point

At a usual heart rate, estimate MAP for a blood pressure of 120/75 mmHg using MAP≈(SBP+2×DBP)÷3\text{MAP} \approx (\text{SBP} + 2 \times \text{DBP}) \div 3. Enter the value in mmHg.

09
True or false
1 point

Pulmonary artery wedge pressure (PAWP) is a direct measurement of left-ventricular end-diastolic pressure.

  1. A

    True

  2. B

    False

10
Choose one
1 point

A noninvasive monitor provides a cardiac-output estimate that differs from another method during a change in vascular tone. Which interpretation is most appropriate?

  1. A

    They directly measure cardiac output and are unaffected by patient conditions.

  2. B

    They provide indirect estimates that can support assessment and trends, but they are not interchangeable with every other method.

  3. C

    They should replace all invasive measurements whenever a value is available.

  4. D

    They are reliable only when cardiac rhythm is irregular.

11
Choose all
1 point

A patient develops worsening hypotension and altered mental status while the monitor displays an unexpected value. Select all appropriate actions.

  1. A

    Assess the patient and consider the pattern across repeated measurements.

  2. B

    Assume a single unexpected value is accurate if the monitor is on.

  3. C

    Verify concerning changes promptly and alert the appropriate clinical team.

  4. D

    Follow local escalation procedures and do not delay care while troubleshooting.

  5. E

    Wait for another isolated abnormal value before assessing the patient.

12
Open ended
1 point

Describe at least two risks of an arterial catheter and at least two precautions that help reduce harm during ongoing line care.

13
Choose one
1 point

A blood-pressure cuff reading seems higher than expected. Which cuff-sizing problem could have produced a falsely high result?

  1. A

    The cuff is too large for the arm.

  2. B

    The cuff is too small for the arm.

  3. C

    The arm is supported at heart level.

  4. D

    The patient is sitting quietly.

14
Choose one
1 point

A patient has cool hands and signs of worsening circulation, but the pulse oximeter displays a reassuring SpO₂. What is the most appropriate response?

  1. A

    Accept the reading because pulse oximeters directly measure blood oxygen content.

  2. B

    Increase oxygen solely because the patient’s hands feel cool.

  3. C

    Assess the patient and signal quality, and verify the reading using appropriate clinical methods.

  4. D

    Assume the displayed pulse rate confirms the oxygen-saturation value is accurate.

15
Choose one
1 point

An arterial pressure transducer is positioned above the reference level specified by protocol. The displayed pressure is lower than expected. Which interpretation and action are appropriate?

  1. A

    Re-level the transducer to the specified reference point; a transducer positioned too high can read falsely low.

  2. B

    Accept the reading because transducer height affects only the waveform shape.

  3. C

    Move the transducer lower than the reference point to correct a falsely low reading.

  4. D

    Zero the system to the patient’s systolic pressure.

16
Choose one
1 point

An arterial-line system fails its fast-flush test in a way consistent with overdamping. What effect may this have on the displayed pressures?

  1. A

    It may exaggerate systolic pressure and produce ringing.

  2. B

    It may underestimate systolic pressure and overestimate diastolic pressure.

  3. C

    It affects only the displayed heart rate, not arterial pressure.

  4. D

    It proves that the patient’s true pulse pressure is narrow.

17
Choose one
1 point

A patient’s CVP is elevated while receiving positive-pressure ventilation. Which approach best reflects the limitations of this measurement?

  1. A

    Use the CVP alone to determine the patient’s intravascular volume.

  2. B

    Treat a low CVP as proof that fluid administration will improve cardiac output.

  3. C

    Interpret the CVP in context, including the patient’s condition and factors that affect the measurement.

  4. D

    Use CVP as a direct measurement of left-ventricular end-diastolic pressure.

18
Written response
1 point

At a usual heart rate, estimate MAP using MAP≈(SBP+2×DBP)÷3\mathrm{MAP} \approx (\mathrm{SBP} + 2 \times \mathrm{DBP}) \div 3. If SBP is 126 mmHg and DBP is 72 mmHg, what is the estimated MAP?

19
Written response
1 point

What is the commonly used reference point that approximates right-atrial level when leveling an arterial pressure transducer, subject to local protocol?

20
Choose all
1 point

Select all findings that may signal hemodynamic deterioration and warrant prompt clinical assessment.

  1. A

    New altered mental status

  2. B

    A single unchanged blood-pressure reading in a patient with no other changes

  3. C

    Cool or mottled skin with weak pulses

  4. D

    Declining urine output