3 Cardiac Output and Cardiac Index
Learn how cardiac output and cardiac index are calculated, measured, influenced by cardiovascular factors, and interpreted alongside clinical findings.
and
(CO) is the volume of blood pumped by a ventricle each minute and is usually reported in . In a stable circulation, right- and left-ventricular outputs are approximately equal.
(SV) is the volume ejected with each heartbeat. depends on heart rate and :
If is measured in and heart rate in , the product is in . Divide by to convert it to . For example, multiplied by gives , or .
can also be found from ventricular volumes:
Here, is end-diastolic volume and is end-systolic volume.
Adjusting for body size
(CI) adjusts for body size by dividing by body surface area (BSA):
is reported in . A commonly cited adult resting reference range is approximately , while is often approximately . These values are guides, not stand-alone diagnostic cutoffs: reference ranges vary among sources and patients.
For example, if is and body surface area is , then:
Indexing helps compare flow across people of different body sizes, but it does not replace assessment of the patient’s condition and perfusion.
Methods for determining
When heart rate and are known or estimated, calculate using . Other methods estimate output using oxygen measurements, temperature change, or echocardiographic flow measurements.
The calculates flow from oxygen consumption and the difference between arterial and mixed-venous oxygen content:
Here, is oxygen consumption, and the denominator represents arterial oxygen content minus mixed-venous oxygen content. For the result to be in , use in and the oxygen-content difference in . Oxygen content matters; oxygen saturation alone is not the same as oxygen content. Accurate oxygen measurements and a sufficiently steady state are needed, and rapid changes in the patient can reduce accuracy.
With a pulmonary artery catheter, a known amount of cooler injectate is introduced into the right atrium. A downstream temperature sensor records the resulting change in blood temperature, and the monitor estimates flow from the temperature–time curve. Faster flow produces a shorter, smaller temperature change; slower flow produces a larger, more prolonged change. Technique, rhythm, and conditions such as significant tricuspid regurgitation can affect the result.
can estimate forward through the left ventricular outflow tract (LVOT):
is then calculated as:
The LVOT area is calculated from its diameter, so diameter measurement error can affect the calculated . Rhythm irregularity and image quality also matter.
Factors that influence output
depends on heart rate and . is influenced mainly by , , and , and these effects interact. A change in one factor does not always produce a predictable change in overall output.
Heart rate and rhythm: A faster heart rate can raise output when the heart can fill and eject effectively. Very rapid rates may shorten filling time and lower ; bradycardia may also reduce output. Irregular rhythms can make both output and its measurement variable.
: This describes ventricular filling and stretch at the end of diastole. Within limits, greater filling can increase through the . Too little filling, such as with blood or fluid loss, may reduce . More is not always beneficial, especially when the heart is failing or congested.
: This is the strength of contraction at a given loading condition. Reduced , as in myocardial injury or heart failure, can lower ; increased sympathetic stimulation or inotropic support may raise it.
: This is the load or resistance the ventricle must overcome to eject blood. Increased can reduce , particularly when ventricular function is impaired. Reduced may allow greater forward ejection.
Venous return, vascular tone, temperature, metabolic demand, medications, oxygen delivery, and underlying heart or lung disease can also alter , directly or through these determinants.
Interpreting values in context
A cardiac-output or cardiac-index value is one part of assessment, not a complete measure of organ perfusion. Interpret it alongside the measurement method, trends, heart rate and rhythm, blood pressure, mental status, skin temperature, urine output, and other clinical findings.
A changing value or signs of worsening perfusion warrant prompt clinical assessment. Do not infer adequate perfusion from blood pressure or from a single cardiac-output or cardiac-index value alone.
For example, if is and heart rate is , is , or . If heart rate rises substantially but falls because filling time is reduced, the higher heart rate may not compensate; may stay the same or decrease.