Reading Regression Diagnostics
A practical guide to using regression diagnostics to investigate model assumptions, unusual observations, and overall adequacy.
What Patterns Reveal
Start with residuals
For observation , the is
where is the observed response and is the model’s fitted response. A is an estimate of an unobserved model error. In a well-specified model, residuals should generally fluctuate around zero without a systematic pattern.
Plot residuals against fitted values and, in multiple regression, against each predictor. A roughly horizontal, pattern-free cloud supports the chosen model form, but it does not prove that the assumptions hold. A smooth curve can help reveal subtle structure. Standardized or studentized residuals can be useful when comparing observations because they account for differences in scale.
Check the pattern and its implications
Linearity. Curves, waves, or other systematic trends in residuals suggest that the mean response may not change linearly as modeled. The source example is a useful pattern to interpret: if residuals are mostly positive at low and high fitted values but negative in the middle, the straight-line model tends to underpredict at both ends and overpredict in the middle. That systematic sequence can indicate missing curvature. A scientifically justified transformation, polynomial term, or other model form may be worth considering; complexity should not be added merely to erase a plot pattern.
Independence. Assess this chiefly from how the data were collected, not from one plot. Repeated measurements, household or classroom clusters, and time-ordered data can produce related errors. Plot residuals against time, collection order, or group: trends, cycles, runs, or clusters suggest dependence not captured by the fitted regression. If the design includes repeated observations or groups, use a model or inference method suited to that structure rather than treating observations as independent. A plot is a warning diagnostic, not a definitive test of independence.
Constant variance. The error spread should be approximately similar across predictor or fitted-value levels. In a plot, compare the cloud’s vertical width across the horizontal range. A widening or narrowing fan suggests . This can make conventional standard errors, confidence intervals, and tests unreliable, even when coefficient estimates remain useful under other conditions. Depending on context, possible responses include modeling the variance, using -robust standard errors, or transforming the response.
distribution. A compares ordered residuals with what would be expected under a normal distribution. Points approximately following a straight line are consistent with normal errors; pronounced bending or departures in the tails may indicate skewness, heavy tails, or outliers. A histogram can also help. Normality matters chiefly for the accuracy of conventional small-sample tests and confidence intervals. It is the residuals—not the predictors—that are assessed for this assumption. Interpret departures in light of sample size and the analysis’s purpose rather than treating a plot or formal test as a pass/fail verdict.
Unusual and Influential Cases
Three related but distinct flags
An has an unusually large : its observed response is poorly predicted. A high-leverage observation has an unusual combination of predictor values. An influential observation materially changes the fitted model when included or excluded.
These descriptions are not interchangeable. A point can have without a large , and a large- point need not strongly change the regression. So do not infer influence from size alone. Examine residuals together with leverage and influence diagnostics, such as Cook’s distance.
When a case looks unusual, check data quality and the context in which it was recorded. No single cutoff should replace judgment. If an influential case is valid, do not delete it merely because it changes the result; report sensitivity to influential cases when relevant.
Judging Model Adequacy
Combine diagnostics with judgment
A high does not guarantee that a model’s form is appropriate or that its assumptions hold. plots can reveal structure left unexplained even when a fit statistic looks strong. Conversely, a random-looking cloud supports adequacy but does not establish it.
Use diagnostics as evidence to investigate: identify a pattern, consider whether it has a substantive explanation, and revise the model only when that revision is justified. Then inspect the diagnostics again to see what the revised model leaves behind. Plots do not automatically prove a problem, validate a model, or justify removing data; goodness-of-fit statistics alone cannot validate a regression either.
: A measure of fit that, by itself, does not establish that a regression model is appropriate or that its assumptions hold.