True or false: HFCs have zero ozone-depletion potential, so they necessarily have low global-warming potential.
1 Refrigerant Types and Properties Online Quiz Questions
Use this free practice quiz with 20 questions to review 1 Refrigerant Types and Properties, test your knowledge, and prepare for your next test or exam.
A refrigerant is classified A2L. Which interpretation of that safety group is correct?
- A
Higher toxicity and mild flammability
- B
Lower toxicity and mild flammability
- C
Lower toxicity and no flame propagation in the standard test
- D
Lower toxicity and high flammability
R-22 belongs to the family, whose refrigerants are ozone-depleting but generally less so than CFCs.
What 100-year global-warming-potential value is listed for R-410A under the cited EPA values?
Which refrigerant is widely used in newer vehicle air-conditioning systems?
- A
R-12
- B
R-404A
- C
R-1234yf
- D
R-717
What refrigerant designation is used for carbon dioxide in commercial and industrial refrigeration systems?
During service, technicians should refrigerant into an appropriate cylinder rather than release it.
Select all characteristics that apply to hydrocarbon refrigerants such as R-600a and R-290.
- A
They have very low global-warming potential.
- B
They are nonflammable under the standard test.
- C
They have zero ozone-depletion potential.
- D
They are highly flammable and classified A3.
True or false: Once a refrigerant's family is known, its pressure can be treated as a fixed value regardless of temperature and condition.
- A
True
- B
False
A technician arrives to service equipment with an unfamiliar refrigerant charge. What should the technician do before connecting gauges or recovery equipment?
- A
Infer the refrigerant from the equipment's age and connect gauges.
- B
Identify the refrigerant from the equipment label before connecting gauges.
- C
Choose a refrigerant from the same family and use its pressure chart.
- D
Connect recovery equipment first and identify the refrigerant afterward.
A technician must service equipment containing a flammable refrigerant. Select all appropriate precautions.
- A
Use equipment rated for the refrigerant and its pressures.
- B
Ventilate the work area.
- C
Assume ignition sources need no special control if the refrigerant has low GWP.
- D
Control ignition sources.
Ammonia is classified B2L. Which interpretation best explains why its safety controls must address more than flammability?
- A
Lower toxicity and mild flammability
- B
Higher toxicity and high flammability
- C
Higher toxicity and mild flammability
- D
Lower toxicity and no flame propagation in the standard test
An equipment owner wants to choose a refrigerant based only on its global-warming potential. Explain why that is not enough to determine whether the refrigerant is suitable and what else can affect its actual environmental impact.
Which refrigerant is widely used in newer vehicle air-conditioning systems?
- A
R-12
- B
R-1234yf
- C
R-404A
- D
R-717
R-1234yf is classified A2L. What does this classification indicate?
- A
Higher toxicity and mild flammability
- B
Lower toxicity and no flame propagation in the standard test
- C
Lower toxicity and mild flammability
- D
Lower toxicity and high flammability
A technician needs to assess pressure for a refrigerant in a particular system. Which approach is appropriate?
- A
Check the equipment nameplate and manufacturer service data, using the correct pressure–temperature chart.
- B
Estimate pressure from the refrigerant family and compare it with a conventional AC system.
- C
Use a pressure value from another refrigerant in the same family.
- D
Select a safe operating pressure from the refrigerant designation alone.
A replacement refrigerant is being considered for a system. Which choice best accounts for equipment compatibility?
- A
Choose whichever refrigerant has the lowest GWP, regardless of the equipment specification.
- B
Substitute a refrigerant with a similar safety classification.
- C
Use any refrigerant in the same family as the specified refrigerant.
- D
Use only the refrigerant specified for the equipment.
During service, intentionally releasing refrigerant into the air is prohibited for ozone-depleting refrigerants and most substitutes.
- A
True
- B
False
Enter the ASHRAE safety group code for a refrigerant classified as higher toxicity and mild flammability.
What is the listed 100-year GWP of R-404A under the cited EPA values?
Related study packs and tools
- Quiz
1 High- and Very-High-Pressure Refrigeration Systems
A medium-difficulty quiz on EPA pressure categories, refrigeration-cycle components, pressure behavior, and safety hazards.
EPA 608 Type IIUpdated - Quiz
2 Refrigerant Pressure Fundamentals
A medium-difficulty quiz on refrigerant pressure, saturation temperature, and interpreting system measurements.
EPA 608 RefrigerantsUpdated - Quiz
3 Leak Detection, Repair, and Verification
A medium-difficulty quiz on locating refrigerant leaks, performing repairs safely, verifying system integrity, and applying relevant regulatory requirements.
EPA 608 Type IIUpdated - Quiz
3 Safe Refrigerant Handling
A medium-difficulty quiz on applying safe refrigerant-handling practices, including hazard recognition, protective measures, leak response, and exposure response.
EPA 608 CoreUpdated - Quiz
5 Appliance Servicing and Return to Service
A medium-difficulty quiz on diagnosing, repairing, testing, and documenting appliance service work before returning equipment to operation.
EPA 608 Type IIUpdated - Study guide
5 Appliance Servicing and Return to Service
A practical sequence for diagnosing, repairing, testing, and documenting refrigeration appliances before returning them to service.
EPA 608 Type IIUpdated - Quiz
5 Chiller Service Practice and Verification
Practice chiller recovery, safety checks, endpoint verification, and service documentation. Follow equipment-specific procedures and applicable requirements.
EPA 608 Type IIIUpdated - Study guide
5 Chiller Service Practice and Verification
A practical framework for safely recovering refrigerant from chillers, verifying recovery and dehydration endpoints, troubleshooting problems, and documenting service work.
EPA 608 Type IIIUpdated - Quiz
5 Refrigerant Compliance Practice
Practice applying refrigerant compliance rules to equipment identification, refrigerant handling, technician qualifications, transfers, and recordkeeping.
EPA 608 CoreUpdated - Study guide
5 Refrigerant Compliance Practice
A practical guide to checking refrigerant rules, assigning work appropriately, preventing releases, handling recovered refrigerant, and keeping the records required for specific jobs.
EPA 608 CoreUpdated - Quiz
5 Small Appliance Service and Compliance Workflows
A medium-difficulty quiz on identifying small appliances and applying Section 608 service, recovery, leak-check, and disposal practices.
EPA 608 Type IUpdated - Quiz
6 Integrated Practice and Competency Checks
A medium-difficulty quiz on safe, compliant service decisions for stationary refrigeration and air-conditioning equipment.
EPA 608 Type IIUpdated