A patient is apneic despite receiving supplemental oxygen. Which response addresses the immediate problem most directly?
3 Oxygen Delivery and Monitoring Online Quiz Questions
Use this free practice quiz with 20 questions to review 3 Oxygen Delivery and Monitoring, test your knowledge, and prepare for your next test or exam.
A patient needs a simple face mask. What is the minimum flow rate at which it should be used?
- A
4 L/min
- B
5 L/min
- C
6 L/min
- D
10 L/min
A patient needs a more controlled oxygen concentration while oxygen is titrated to a prescribed target. Which device is the best match?
- A
Nasal cannula
- B
Simple face mask
- C
Venturi (air-entrainment) mask
- D
Reservoir mask (non-rebreather)
A spontaneously breathing patient with severe hypoxemia is being placed on a reservoir mask while urgent assessment occurs. Which actions are appropriate? Select all that apply.
- A
Inflate the reservoir before applying the mask.
- B
Use a high flow according to the mask instructions, commonly 10–15 L/min.
- C
Use it instead of assisted ventilation whenever the patient’s breathing is inadequate.
- D
Check that the reservoir does not collapse substantially during inspiration.
True or false: A reassuring SpO₂ reading by itself rules out inadequate ventilation or carbon-dioxide retention.
- A
True
- B
False
True or false: Oxygen-enriched environments can make fires start more easily and burn more intensely.
- A
True
- B
False
A spontaneously breathing adult has a modest oxygen need and is using a nasal cannula. What is the commonly used upper-end flow rate? Enter the value in L/min.
What oxygen-delivery device is useful when a more controlled oxygen concentration is needed? Enter the device name.
For many adults at risk of hypercapnic respiratory failure, a commonly used SpO₂ target range is ; follow the prescribed target and local protocol.
When documenting saturation, record the oxygen-delivery and its flow or FiO₂. The same SpO₂ on different levels of support does not indicate the same .
A patient receiving high-flow nasal cannula has worsening respiratory distress and is not improving. Explain what should happen next and what you would reassess.
Which description best matches high-flow nasal cannula (HFNC) when considered for acute hypoxemic respiratory failure?
- A
A device intended only for patients who need a modest oxygen flow while eating.
- B
A mask that delivers a more controlled oxygen concentration through an adapter.
- C
Heated, humidified gas delivered at high flow with adjustable FiO₂ in an appropriately monitored setting.
- D
A mask that should be used below 5 L/min to prevent carbon-dioxide accumulation.
Which factors or limitations can affect the accuracy or interpretation of pulse oximetry? Select all that apply.
- A
Poor circulation
- B
Cold skin
- C
Movement
- D
Nail products
- E
A stable respiratory rate
- F
Pulse oximetry overestimating oxygenation in some people with darker skin
True or false: Supplemental oxygen by itself corrects inadequate breathing and removes carbon dioxide.
- A
True
- B
False
A spontaneously breathing adult needs a simple face mask. What is the minimum flow rate recommended to reduce the risk of exhaled carbon dioxide accumulating in the mask?
- A
2 L/min
- B
5 L/min
- C
12 L/min
- D
15 L/min
For an adult at risk of hypercapnic respiratory failure, the common SpO₂ target range is 88–92%. What is the lower boundary of that range? Give your answer as a percentage-point value.
A spontaneously breathing adult has a modest oxygen need and wants to keep talking and eating. Which flow range is commonly used with a nasal cannula?
- A
0.5–2 L/min
- B
5–10 L/min
- C
1–6 L/min
- D
10–15 L/min
A patient needs oxygen at a more controlled concentration while oxygen is titrated to a prescribed target. Which device is most suited to this need?
- A
Nasal cannula
- B
Simple face mask
- C
Reservoir mask
- D
Venturi mask
What is one substance that must be kept away from oxygen fittings?
A spontaneously breathing adult has severe hypoxemia while urgent assessment and escalation are being arranged. Which plan for a reservoir mask is appropriate?
- A
Use it for severe hypoxemia while arranging urgent assessment; inflate the reservoir before applying it.
- B
Use it for inadequate breathing instead of assisted ventilation; leave the reservoir empty.
- C
Use it for modest oxygen needs; run it below 5 L/min to prevent carbon dioxide buildup.
- D
Use it to deliver a controlled oxygen concentration; cover its air-entrainment ports.