True or false: A technician should not rely on the absence of refrigerant odor to decide that an enclosed work area is safe.

  1. A

    True

  2. B

    False

02
Written response
1 point

For routine refrigerant service, what type of gloves helps protect against splashes and frostbite?

03
True or false
1 point

True or false: When a splash risk calls for a face shield, it should be worn with suitable eye protection rather than replacing it.

  1. A

    True

  2. B

    False

04
Fill in the blank
1 point

To prevent cross-contamination, do not in a recovery cylinder.

05
True or false
1 point

True or false: An ordinary air-purifying respirator is adequate protection for a worker entering an area where a refrigerant release may have caused oxygen deficiency.

  1. A

    True

  2. B

    False

06
Written response
1 point

What piece of equipment can a technician use to locate a refrigerant leak?

07
Choose one
1 point

A leak detector indicates a leak at a service connection. Which response best follows safe work practices?

  1. A

    Continue working and add refrigerant to compensate for the leak.

  2. B

    Stop work, isolate the equipment if safe, ventilate as appropriate, repair or replace the faulty connection, and verify the repair.

  3. C

    Use an open flame to find the exact leak location before deciding what to do.

  4. D

    Disconnect the service connection immediately without first assessing whether it is safe.

08
Fill in the blank
1 point

After repairing a leak, before returning the equipment to service.

09
Choose all
1 point

Before servicing equipment, which actions help assess and control the job's hazards? Select all that apply.

  1. A

    Identify the refrigerant and check its safety data sheet and equipment instructions.

  2. B

    Rely on smell to determine whether the air is safe.

  3. C

    Assess the amount that could escape and any ignition sources.

  4. D

    Work in an appropriately ventilated area.

10
Choose all
1 point

A significant refrigerant leak is suspected. Which actions are appropriate? Select all that apply.

  1. A

    Warn others and leave the affected area.

  2. B

    Call emergency services or the site emergency contact.

  3. C

    Enter the area to rescue someone even if you are untrained and unequipped.

  4. D

    Allow only trained responders to re-enter after the atmosphere is assessed and declared safe.

11
Choose one
1 point

A technician needs to open a pressurized refrigerant line. What must happen before the line is opened?

  1. A

    Open the line first, then isolate the system if refrigerant escapes.

  2. B

    Use a leak detector to confirm the line is empty without changing its pressure state.

  3. C

    Safely isolate and depressurize the system before opening the line.

  4. D

    Vent refrigerant from the line to reduce its pressure.

12
Choose one
1 point

Which setup is appropriate for recovering refrigerant from equipment?

  1. A

    Use any recovery machine and an unlabeled cylinder if the refrigerant is recovered slowly.

  2. B

    Use recovery equipment approved for the refrigerant and a compatible, properly labeled recovery cylinder.

  3. C

    Use a cylinder containing a different refrigerant to avoid needing a new container.

  4. D

    Release some refrigerant before recovery to reduce pressure in the cylinder.

13
Open ended
1 point

A worker may have inhaled refrigerant. Explain what to do, including how to move the person, when to call for help, and when resuscitation may be started.

14
Choose one
1 point

You are preparing to service equipment, but you do not yet know which refrigerant it contains. What should you do before beginning work?

  1. A

    Begin work using the procedures for the refrigerant most commonly used in similar equipment.

  2. B

    Identify the refrigerant and check its safety data sheet and equipment instructions.

  3. C

    Start the equipment briefly to see whether any refrigerant escapes.

  4. D

    Rely on smell to decide whether the refrigerant is safe to handle.

15
Choose one
1 point

A service task must be done in a low-lying, poorly ventilated area where refrigerant could escape. Which approach best addresses the risk that refrigerant could displace oxygen?

  1. A

    Work without ventilation if the refrigerant has little or no noticeable odor.

  2. B

    Use a fan only after a worker notices symptoms of exposure.

  3. C

    Provide appropriate ventilation, using suitable mechanical ventilation when needed, and do not rely on smell to assess air safety.

  4. D

    Close the work area to keep refrigerant from spreading into other spaces.

16
Choose one
1 point

A technician needs to open a pressurized refrigerant line. Which action must be taken before opening it?

  1. A

    Safely isolate and depressurize the line before opening it.

  2. B

    Loosen a fitting slowly so pressure can escape during the work.

  3. C

    Open the line only after putting on a face shield.

  4. D

    Keep the system running so pressure remains stable as the line is opened.

17
Choose one
1 point

A task-specific risk assessment indicates that liquid refrigerant could splash toward a worker’s face. Which PPE approach is appropriate?

  1. A

    Use a face shield in place of eye protection whenever a splash is possible.

  2. B

    Wear only ordinary gloves because eye injuries are unlikely during refrigerant service.

  3. C

    Choose PPE based on appearance rather than the refrigerant or task.

  4. D

    Use suitable eye protection and, when splash risk calls for it, wear a face shield with that eye protection.

18
Choose one
1 point

A worker needs to locate a suspected refrigerant leak. Which method is appropriate?

  1. A

    Apply an open flame near the suspected leak and watch for a change.

  2. B

    Use a leak detector or another suitable leak-check method, not an open flame.

  3. C

    Add refrigerant until the leak becomes easier to locate by smell.

  4. D

    Assume the leak is fixed once the fitting has been tightened.

19
Written response
1 point

In the United States, which EPA section prohibits intentionally venting covered refrigerants during equipment service, repair, or disposal? Enter the section number.

20
Written response
1 point

What specific atmospheric hazard can an ordinary air-purifying respirator not protect against during an unknown refrigerant release?