What term describes removing refrigerant from an appliance and storing it in an external container without requiring cleaning or testing?
5 Refrigerant Recovery and Practical Review Online Quiz Questions
Use this free practice quiz with 20 questions to review 5 Refrigerant Recovery and Practical Review, test your knowledge, and prepare for your next test or exam.
A recovery cylinder is a pressure vessel, not a .
Under Section 608, recycled refrigerant from stationary equipment may be reused in equipment owned by the same person, but recycling does not provide the purity verification required for reclamation.
- A
True
- B
False
A contractor recovers clean refrigerant from a customer's stationary appliance. The contractor wants to sell it to a different owner. What must generally happen first?
- A
Sell it because it appears clean.
- B
Have it reclaimed by an EPA-certified reclaimer before sale to the new owner.
- C
Filter it on site and sell it as reclaimed refrigerant.
- D
Mix it with new refrigerant before sale.
Refrigerant is unknown or may be mixed. How should it be handled relative to a cylinder containing known refrigerant? Enter one verb.
For servicing or disposal, recover to the evacuation level required for the and applicable rules; do not assume one target applies to every appliance.
A technician is servicing a stationary air-conditioning appliance. Which recovery machine should the technician use?
- A
Any machine that can connect to the hoses is acceptable.
- B
Use whichever recovery machine is available, even if its certification is for another appliance type.
- C
Use recovery equipment certified for the applicable use and suitable for that refrigerant.
- D
Use recycling equipment instead, because it cleans the refrigerant during recovery.
Motor vehicle air conditioners are generally handled under Section 609 requirements rather than the ordinary stationary-equipment workflow described here.
- A
True
- B
False
Before recovering refrigerant, which actions are appropriate when preparing the work area? Select all that apply.
- A
Read the equipment label and assess whether the refrigerant is flammable or presents other special hazards.
- B
Provide ventilation, keep ignition sources away when required, and use appropriate eye and hand protection.
- C
Assume an unknown refrigerant is nonflammable unless a hazard becomes apparent during recovery.
- D
Follow the safety instructions for the equipment and refrigerant.
Which practices help manage a recovery cylinder safely during and after filling? Select all that apply.
- A
Check the cylinder markings, tare weight, rated capacity, and any fill-control device.
- B
Weigh the cylinder before and during recovery, and stop at its applicable maximum fill weight.
- C
Continue filling while pressure appears acceptable, even if the maximum fill weight may have been reached.
- D
Secure the cylinder against falling and keep it away from excessive heat.
During recovery, a cylinder becomes warm and its pressure is high. What should the technician do?
- A
Release refrigerant until the pressure drops, then resume work.
- B
Cool the cylinder by placing it in water and continue filling.
- C
Do not vent it; keep it away from heat and follow safe handling procedures, stopping work and following the emergency procedure if it appears unsafe.
- D
Open the cylinder valve briefly to confirm whether pressure is still rising.
What tool should a technician use to measure a recovery cylinder's mass before and during recovery?
When closing out a recovery job, what should the technician do about refrigerant trapped in the hoses?
- A
Open the hose connection quickly so the trapped refrigerant escapes before the hoses are stored.
- B
Close the valves and prevent refrigerant trapped in the hoses from being released.
- C
Leave the valves open so pressure can equalize with the work area.
- D
Vent the hose contents only if the recovery cylinder is full.
A technician is about to recover refrigerant from a stationary appliance whose label identifies a flammable refrigerant. Describe a safe recovery plan from preparation through cylinder closeout. Explain why a setup that is merely able to connect to the hoses may not be suitable.
Before beginning recovery, what should a technician read to identify the refrigerant and assess its hazards?
A batch of used refrigerant is reprocessed to applicable purity specifications, and its quality is verified by the prescribed analytical method. What level of refrigerant handling is this?
- A
Filtering recovered refrigerant for reuse without verifying its purity
- B
Reprocessing refrigerant to applicable purity specifications and verifying its quality
- C
Removing refrigerant from an appliance and storing it without cleaning or testing
- D
Combining different refrigerants to make a reusable charge
A recovery machine’s fittings connect to a stationary appliance, but its certification and refrigerant suitability have not been checked. What should the technician do?
- A
Any machine that fits the hoses, provided the technician is certified
- B
Any machine that has previously been used on stationary equipment
- C
Equipment certified for the applicable use and suitable for the refrigerant
- D
Only equipment that can recover liquid, regardless of its certification
A contractor has recovered refrigerant from a customer’s stationary appliance. The refrigerant appears clean, but the contractor wants to sell it to a different owner. What must generally happen first?
- A
Have it reclaimed by an EPA-certified reclaimer before selling it to the new owner
- B
Sell it as usable refrigerant because it appears clean
- C
Filter it and sell it without verifying its purity
- D
Mix it with refrigerant owned by the new customer
A refrigerant’s label indicates a flammability hazard. Which preparation best follows the safe-work guidance before recovery begins?
- A
Begin recovery immediately, then assess ventilation if a problem occurs
- B
Follow the safety instructions, provide ventilation, and keep ignition sources away when required
- C
Rely on cylinder pressure to determine whether the work area is safe
- D
Use eye protection only; refrigerant hazards do not require other precautions
A recovery cylinder is warm and its pressure is high. The technician should release refrigerant to reduce the pressure.
- A
True
- B
False
Related study packs and tools
- Quiz
1 High- and Very-High-Pressure Refrigeration Systems
A medium-difficulty quiz on EPA pressure categories, refrigeration-cycle components, pressure behavior, and safety hazards.
EPA 608 Type IIUpdated - Study guide
1 Refrigerant Types and Properties
Learn how refrigerant families differ in applications, environmental effects, operating conditions, safety classifications, equipment compatibility, and handling requirements.
EPA 608 RefrigerantsUpdated - Flashcards
3 Environmental Effects and Refrigerant Regulations
Learn how refrigerants affect ozone and climate, how regulations govern their use, and how to handle and select them responsibly.
EPA 608 RefrigerantsUpdated - Study guide
3 Environmental Effects and Refrigerant Regulations
Learn how refrigerants affect ozone and climate, how regulations govern their use and release, and what environmental and safety factors shape refrigerant selection.
EPA 608 RefrigerantsUpdated - Quiz
3 Safe Refrigerant Handling
A medium-difficulty quiz on applying safe refrigerant-handling practices, including hazard recognition, protective measures, leak response, and exposure response.
EPA 608 CoreUpdated - Flashcards
4 Safe Refrigerant Handling
Learn how to identify refrigerants, manage their hazards, recover and handle them safely, and prevent leaks.
EPA 608 RefrigerantsUpdated - Quiz
4 Safe Refrigerant Handling
A medium-difficulty quiz on identifying refrigerants, managing hazards, using equipment safely, preventing leaks, and handling cylinders.
EPA 608 RefrigerantsUpdated - Quiz
5 Chiller Service Practice and Verification
Practice chiller recovery, safety checks, endpoint verification, and service documentation. Follow equipment-specific procedures and applicable requirements.
EPA 608 Type IIIUpdated - Study guide
5 Chiller Service Practice and Verification
A practical framework for safely recovering refrigerant from chillers, verifying recovery and dehydration endpoints, troubleshooting problems, and documenting service work.
EPA 608 Type IIIUpdated - Quiz
5 Refrigerant Compliance Practice
Practice applying refrigerant compliance rules to equipment identification, refrigerant handling, technician qualifications, transfers, and recordkeeping.
EPA 608 CoreUpdated - Study guide
5 Refrigerant Compliance Practice
A practical guide to checking refrigerant rules, assigning work appropriately, preventing releases, handling recovered refrigerant, and keeping the records required for specific jobs.
EPA 608 CoreUpdated - Quiz
5 Small Appliance Service and Compliance Workflows
A medium-difficulty quiz on identifying small appliances and applying Section 608 service, recovery, leak-check, and disposal practices.
EPA 608 Type IUpdated