Timedora
Free Practice Quiz Question List

Heat Exchanger Analysis Quiz Online Quiz Questions

Use this free practice quiz with 10 questions to review Heat Exchanger Analysis, test your knowledge, and prepare for your next test or exam.

10 questions
01
Choose one
1 point

At the same NTU and capacity-rate ratio, which statement generally compares the effectiveness of single-pass counterflow and parallel-flow exchangers?

  1. A

    Parallel flow is generally more effective.

  2. B

    Counterflow is generally more effective.

  3. C

    They are always equally effective.

  4. D

    Effectiveness depends only on exchanger area.

02
Choose one
1 point

A heat exchanger has effectiveness 0.750.75, minimum heat-capacity rate 2 kW/K2\ \mathrm{kW/K}, and inlet temperatures Th,i=140∘CT_{h,i}=140^\circ\mathrm{C} and Tc,i=30∘CT_{c,i}=30^\circ\mathrm{C}. What is its heat-transfer rate?

  1. A

    82.5 kW82.5\ \mathrm{kW}

  2. B

    150 kW150\ \mathrm{kW}

  3. C

    165 kW165\ \mathrm{kW}

  4. D

    210 kW210\ \mathrm{kW}

03
Choose one
1 point

An engineer knows both streams’ inlet and outlet temperatures and wants to determine the heat-transfer area required. Which method is most directly suited to this task?

  1. A

    Use the LMTD method.

  2. B

    Use the effectiveness–NTU method because the outlet temperatures are unknown.

  3. C

    Use the effectiveness–NTU method because only inlet temperatures are available.

  4. D

    Neither method can be used when outlet temperatures are known.

04
Choose one
1 point

For a thin, flat wall with negligible fouling, which expression approximates the overall heat-transfer coefficient using the two convection coefficients and wall properties?

  1. A

    U=1hh+tkw+1hcU=\frac{1}{h_h}+\frac{t}{k_w}+\frac{1}{h_c}

  2. B

    1U=1hh+kwt+1hc\frac{1}{U}=\frac{1}{h_h}+\frac{k_w}{t}+\frac{1}{h_c}

  3. C

    1U=hh+tkw+hc\frac{1}{U}=h_h+\frac{t}{k_w}+h_c

  4. D

    1U≈1hh+tkw+1hc\frac{1}{U}\approx\frac{1}{h_h}+\frac{t}{k_w}+\frac{1}{h_c}

05
Choose one
1 point

A heat exchanger’s inlet temperatures and UAUA are known, but its outlet temperatures are unknown. Which method is the appropriate choice?

  1. A

    Use LMTD because it requires only inlet temperatures and UAUA.

  2. B

    Use LMTD because the outlet temperatures are unknown.

  3. C

    Use effectiveness–NTU because inlet temperatures and UAUA are known, but outlet temperatures are unknown.

  4. D

    Neither method applies unless all four terminal temperatures are known.

06
Choose one
1 point

Assuming negligible heat loss and no phase change, a heat exchanger transfers 80 kW80\ \mathrm{kW}. The hot stream has Ch=4 kW/KC_h=4\ \mathrm{kW/K} and enters at 180∘C180^\circ\mathrm{C}; the cold stream has Cc=2 kW/KC_c=2\ \mathrm{kW/K} and enters at 25∘C25^\circ\mathrm{C}. Which pair of outlet temperatures follows from the energy balances?

  1. A

    Th,o=160∘CT_{h,o}=160^\circ\mathrm{C}, Tc,o=45∘CT_{c,o}=45^\circ\mathrm{C}

  2. B

    Th,o=160∘CT_{h,o}=160^\circ\mathrm{C}, Tc,o=65∘CT_{c,o}=65^\circ\mathrm{C}

  3. C

    Th,o=200∘CT_{h,o}=200^\circ\mathrm{C}, Tc,o=65∘CT_{c,o}=65^\circ\mathrm{C}

  4. D

    Th,o=100∘CT_{h,o}=100^\circ\mathrm{C}, Tc,o=105∘CT_{c,o}=105^\circ\mathrm{C}

07
Choose one
1 point

An exchanger has UA=3 kW/KUA=3\ \mathrm{kW/K} and Cmin⁡=1.5 kW/KC_{\min}=1.5\ \mathrm{kW/K}. What is its NTU?

  1. A

    22

  2. B

    0.50.5

  3. C

    4.54.5

  4. D

    66

08
Choose one
1 point

When a consistent reference area is used, what does the product UAUA represent for a heat exchanger?

  1. A

    UAUA is the hot-side convection coefficient.

  2. B

    UAUA is the wall’s thermal conductivity.

  3. C

    UAUA is the exchanger’s overall thermal conductance.

  4. D

    UAUA is the heat-capacity rate of the smaller stream.

09
Choose one
1 point

If all terminal temperatures are known and the assumptions used by both methods match, how should the heat-transfer rates calculated by LMTD and effectiveness–NTU compare?

  1. A

    LMTD always predicts a larger heat-transfer rate.

  2. B

    Effectiveness–NTU always predicts a larger heat-transfer rate.

  3. C

    They agree only for parallel flow.

  4. D

    They should give the same heat-transfer rate.

10
Choose one
1 point

A passive exchanger has Cmin⁡=1.5 kW/KC_{\min}=1.5\ \mathrm{kW/K}, inlet temperatures Th,i=120∘CT_{h,i}=120^\circ\mathrm{C} and Tc,i=20∘CT_{c,i}=20^\circ\mathrm{C}, and effectiveness 0.80.8. What is the actual heat-transfer rate?

  1. A

    100 kW100\ \mathrm{kW}

  2. B

    120 kW120\ \mathrm{kW}

  3. C

    150 kW150\ \mathrm{kW}

  4. D

    180 kW180\ \mathrm{kW}