Timedora
Free Practice Quiz Question List

Infusion Rate Calculations Online Quiz Questions

Use this free practice quiz with 20 questions to review Infusion Rate Calculations, test your knowledge, and prepare for your next test or exam.

20 questions
01
Choose one
1 point

An order is to infuse 750 mL over 5 hours using tubing labeled 15 gtt/mL. What gravity drip rate should be set, rounded to a whole drop per minute?

  1. A

    37.5 gtt/min

  2. B

    15 gtt/min

  3. C

    750 gtt/min

  4. D

    38 gtt/min

02
Choose all
1 point

Select all statements that correctly describe volume-based infusion pump settings and setup.

  1. A

    For time in hours, calculate mL/hr by dividing the volume in mL by the time in hours.

  2. B

    When time is in minutes, multiply the volume-per-minute rate by 60 to convert it to mL/hr.

  3. C

    A pump setting must always be entered as a whole number, regardless of pump precision or local policy.

  4. D

    Correct setup also depends on selecting the right medication, concentration, volume, and duration.

03
True or false
1 point

True or false: For the hypothetical order of 5 mcg/kg/min for a 70 kg patient, with a solution containing 400 mg in 250 mL, the calculated pump rate is 13.125 mL/hr. This is a math example, not a treatment recommendation.

  1. A

    True

  2. B

    False

04
Written response
1 point

What calculation method tracks units and checks that unwanted units cancel, leaving the requested units?

05
Fill in the blank
1 point

In dimensional analysis, arrange conversion factors so unwanted units and the requested units remain.

06
Open ended
1 point

A volume of 250 mL is to be infused over 90 minutes. Calculate the volume-based pump rate in mL/hr, rounded to the nearest tenth.

07
Choose one
1 point

A hypothetical order is 5 mcg/kg/min for a 70 kg patient, and the solution contains 400 mg in 250 mL. What is the calculated pump rate in mL/hr? This is a math example, not a treatment recommendation.

  1. A

    1.3125 mL/hr

  2. B

    8.4 mL/hr

  3. C

    13.125 mL/hr

  4. D

    21 mL/hr

08
Choose all
1 point

Select all statements that correctly describe calculating and verifying a gravity infusion rate.

  1. A

    Calculate gtt/min by multiplying volume in mL by the tubing’s labeled drop factor in gtt/mL, then dividing by time in minutes.

  2. B

    Convert hours to minutes before using the gravity drip-rate formula.

  3. C

    Use the drop factor printed for the specific tubing set rather than inferring it from the tubing’s appearance.

  4. D

    Infer the drop factor from how the tubing looks if its package label is unavailable.

  5. E

    After setting a gravity infusion, count drops over a full minute to verify the rate.

09
True or false
1 point

True or false: Dimensional analysis tracks units and checks that unwanted units cancel, leaving the requested units; this can help make unit errors easier to detect.

  1. A

    True

  2. B

    False

10
Written response
1 point

For the hypothetical order of 5 mcg/kg/min for a 70 kg patient, with a solution containing 400 mg in 250 mL, what is the unrounded calculated pump rate in mL/hr? This is a math example, not a treatment recommendation.

11
Fill in the blank
1 point

A volume of 250 mL is infused over 90 minutes. The pump rate is mL/hr.

12
Choose one
1 point

A gravity infusion delivers 750 mL over 5 hours using tubing labeled 15 gtt/mL. What is the rate in whole drops per minute, following the supplied example?

  1. A

    37.5 gtt/min

  2. B

    Approximately 38 gtt/min

  3. C

    45 gtt/min

  4. D

    225 gtt/min

13
True or false
1 point

True or false: In an infusion calculation, writing units beside values and checking that unwanted units cancel can help verify that the result has the requested units.

  1. A

    True

  2. B

    False

14
Written response
1 point

A gravity infusion delivers 750 mL over 5 hours through tubing labeled 15 gtt/mL. Using the whole-drop rate shown by the supplied example, what rate in gtt/min should be set?

15
Choose one
1 point

For the hypothetical order of 5 mcg/kg/min for a 70 kg patient, with a solution containing 400 mg in 250 mL, what is the calculated pump rate in mL/hr before rounding?

  1. A

    1.3125 mL/hr

  2. B

    13.1 mL/hr

  3. C

    13.125 mL/hr

  4. D

    131.25 mL/hr

16
Written response
1 point

What is the calculation method called when units are tracked through a calculation and conversion factors are arranged so unwanted units cancel?

17
Choose one
1 point

Which method correctly calculates a concentration-based infusion pump rate in mL/hr from a dose-based order?

  1. A

    Divide the dose per minute by the concentration without converting the time unit.

  2. B

    Convert the ordered dose to an amount per hour, then divide by the solution concentration expressed as drug amount per volume.

  3. C

    Multiply the solution concentration by the patient's weight, then divide by the infusion time in minutes.

  4. D

    Divide the ordered volume by the patient's weight and report the result in gtt/min.

18
Choose one
1 point

After setting a gravity infusion, which action does the material specify for verifying the rate?

  1. A

    Assume the drop factor from the tubing's appearance and estimate the rate.

  2. B

    Count drops for 15 seconds and report that count as drops per minute.

  3. C

    Count drops over a full minute to verify the set rate.

  4. D

    Use the pump's mL/hr setting to verify a gravity tubing rate.

19
Choose one
1 point

An infusion order is for 750 mL over 5 hours, and the specific tubing set is labeled 15 gtt/mL. What gravity drip rate should be set, rounded to a whole drop per minute?

  1. A

    25 gtt/min

  2. B

    38 gtt/min

  3. C

    150 gtt/min

  4. D

    2250 gtt/min

20
Choose one
1 point

For this math example, a hypothetical order is 5 mcg/kg/min for a 70 kg patient, and the solution contains 400 mg in 250 mL. What is the calculated pump rate in mL/hr before rounding?

  1. A

    0.219 mL/hr

  2. B

    8.75 mL/hr

  3. C

    13.125 mL/hr

  4. D

    21.875 mL/hr