01
Front

What work does EPA Section 608 Type I certification cover?

Back

It covers covered maintenance, service, and repair of small appliances containing refrigerants subject to Section 608 requirements.

02
Front

When does service work require Section 608 certification?

Back

Certification is required when work could reasonably be expected to breach the refrigerant circuit, such as connecting gauges, adding or removing refrigerant, or cutting refrigerant lines.

03
Front

Does external electrical rewiring generally require Section 608 certification?

Back

Routine work that does not affect the refrigerant circuit, such as rewiring an external electrical circuit, generally does not require technician certification.

04
Front

Under what condition may an apprentice perform covered work before certification?

Back

An apprentice may perform covered work before certification only while closely and continually supervised by a properly certified technician.

05
Front

What is the small-appliance disposal exception to certification?

Back

Section 608 certification is not required solely to recover refrigerant from a small appliance at disposal.

06
Front

What qualifies an appliance as a small appliance under 40 CFR § 82.152?

Back

It must be fully manufactured, charged, and hermetically sealed in a factory, and contain five pounds or less of refrigerant.

07
Front

Name a type of air conditioner that can be a small appliance.

Back

Room air conditioners, including window and portable units, are examples of small appliances when they meet the full definition.

08
Front

Is an appliance a small appliance just because it is compact?

Back

No. Compact size or a charge of five pounds or less alone is insufficient; the appliance must also be factory-manufactured, charged, and hermetically sealed.

09
Front

What is the rule on venting covered refrigerant during service or repair?

Back

Do not knowingly vent covered refrigerant during service or repair.

10
Front

What equipment must be used before opening a small appliance?

Back

Before opening a small appliance, use recovery and/or recycling equipment certified for the applicable use.

11
Front

What recovery amount applies when the recovery equipment was manufactured before November 15, 1993?

Back

Recover 80% of the refrigerant.

12
Front

What recovery amount applies to post-November 15, 1993 equipment when the compressor functions?

Back

Recover 90% of the refrigerant.