3 EPA Section 608 Type I Requirements
Learn which appliances Type I certification covers, when certification is required, and the recovery steps required before opening or disposing of a small appliance.
When applies
covers technicians who maintain, service, or repair small appliances containing refrigerants subject to Section 608 requirements. Certification is required when the work could reasonably be expected to breach the . This can include connecting gauges or hoses, adding or removing refrigerant, replacing refrigerant-circuit components, or cutting refrigerant lines.
Routine work that does not affect the , such as rewiring an external electrical circuit, generally does not require technician certification. Certification is based on the appliance type, not simply on the refrigerant used.
A Type I credential is limited to small appliances and does not qualify a technician to service other Section 608 appliance categories. An apprentice may perform covered work before certification only while closely and continually supervised by a properly certified technician. There is a narrow disposal exception: certification is not required solely to refrigerant from a at disposal.
Which appliances qualify
To qualify as a under 40 CFR § 82.152, a device must be fully manufactured, charged, and hermetically sealed in a factory, and contain five pounds or less of refrigerant. All of these criteria matter; compact size or a charge of five pounds or less is not sufficient by itself.
Examples include:
Household, commercial, and consumer refrigerators and freezers
Medical or industrial research refrigeration equipment
Room air conditioners, including window and portable units, and packaged terminal heat pumps
Dehumidifiers
Under-the-counter ice makers
Vending machines
Drinking-water coolers
Recovery before opening or disposal
Do not knowingly vent covered refrigerant during service or repair. Before opening a , use recovery and/or recycling equipment certified for the applicable use. The same requirement applies when recovering refrigerant before disposal.
Under 40 CFR § 82.156(b), the recovery or evacuation options depend on the 's manufacture date and, for equipment manufactured on or after November 15, 1993, whether the compressor functions:
Equipment manufactured before November 15, 1993: of the refrigerant.
Equipment manufactured on or after November 15, 1993, with a functioning compressor: .
Equipment manufactured on or after November 15, 1993, with a nonfunctioning compressor: .
As an alternative, evacuate the appliance to inches of mercury vacuum.
For example, before opening a refrigerator that meets the small-appliance definition, a technician using equipment manufactured on or after November 15, 1993, may if the compressor functions or if it does not. The technician may instead evacuate the appliance to inches of mercury vacuum.
Use according to its manufacturer's instructions unless those instructions conflict with the regulation. EPA requires to meet applicable certification standards. Recovering refrigerant means removing it and storing it in an external container; this process alone does not necessarily clean or reclaim the refrigerant.