01
Front

What qualifies as a small appliance under Section 608 Type I?

Back

Small appliances include factory-charged, hermetically sealed appliances containing five pounds or less of refrigerant, such as household refrigerators and window air conditioners.

02
Front

Which Section 608 requirements govern small-appliance servicing?

Back

Section 608 Type I requirements govern servicing small appliances containing five pounds or less of refrigerant.

03
Front

How does self-contained recovery equipment move refrigerant?

Back

Self-contained equipment uses its own compressor or another means to draw refrigerant from an appliance and move it into an external recovery container.

04
Front

What limits apply to system-dependent recovery equipment?

Back

It relies on the appliance compressor or internal pressure. It may not be used with an appliance containing more than 15 pounds of refrigerant unless permanently attached as a pump-out unit.

05
Front

How should recovery equipment be selected for a small appliance?

Back

Use recovery equipment approved for the appliance and refrigerant being handled, and follow the equipment manufacturer’s instructions.

06
Front

What recovery percentage applies to equipment made before November 15, 1993?

Back

With recovery equipment manufactured before November 15, 1993, recover at least 80% of the refrigerant.

07
Front

What is the recovery target for post-November 14, 1993 equipment with an operational compressor?

Back

Recover at least 90% of the refrigerant when the compressor is operational.

08
Front

What is the recovery target for post-November 14, 1993 equipment with a failed compressor?

Back

Recover at least 80% of the refrigerant when the compressor is not operational.

09
Front

What vacuum endpoint is an alternative to the percentage recovery targets?

Back

Evacuate the appliance to 4 inches of mercury vacuum. This is an alternative compliance method.

10
Front

Do recovery percentages indicate refrigerant pressure?

Back

The percentages describe the amount of refrigerant recovered from the appliance; they are not pressure readings.

11
Front

When may a technician open a small appliance’s sealed system?

Back

Verify the required recovery percentage or the 4-inch-mercury-vacuum endpoint using the prescribed method before opening the sealed system.

12
Front

How do recovery, recycling, and reclamation differ?

Back

Recovery removes refrigerant and stores it in a container; it does not clean it. Recycling cleans refrigerant for reuse, while reclamation processes it to applicable purity specifications.