Study 7 Repair and Post-Service Verification with 12 free online flashcards. Review key terms, definitions, and concepts with this interactive flashcard deck.

12 cards
01
Front

What qualifies as a small appliance under EPA Section 608?

Back

A factory-manufactured, charged, hermetically sealed appliance containing 5 pounds or less of refrigerant.

02
Front

Which Section 608 certification type covers small appliances?

Back

Type I certification covers work on small appliances.

03
Front

Under what supervision may an apprentice perform refrigerant-circuit work?

Back

Apprentices may work under the close and continual supervision of a certified technician.

04
Front

What power-safety step comes before electrical or mechanical work?

Back

Disconnect electrical power before electrical or mechanical work, and follow the manufacturer’s safety instructions.

05
Front

When must refrigerant be recovered before a repair?

Back

Recover the refrigerant first whenever the repair will open the sealed circuit.

06
Front

What is the small-appliance recovery benchmark for a working compressor and newer equipment?

Back

The benchmark is 90% when the compressor works and the recovery equipment was manufactured after November 15, 1993.

07
Front

What evacuation level can alternatively meet the small-appliance recovery requirement?

Back

As an alternative, evacuate the appliance to 4 inches of mercury vacuum.

08
Front

What governs replacement-part and refrigerant selection?

Back

Use a compatible component and follow the appliance manufacturer’s procedure. Do not substitute a refrigerant or component without explicit approval for that appliance.

09
Front

How should open refrigerant tubing be protected during a repair?

Back

Keep the circuit clean and dry, and protect open tubing from dirt and moisture.

10
Front

What can a pressure or vacuum decay check establish about a leak?

Back

Use an appropriate method, such as a compatible electronic detector or approved bubble solution. A pressure or vacuum decay check may show a loss but does not necessarily locate the leak.

11
Front

What must be done about leaks before charging or returning an appliance to service?

Back

Repair leaks before charging or returning the appliance to service, and never intentionally vent refrigerant during servicing.

12
Front

What should be checked before closing the appliance cabinet?

Back

Check tubing support and clearance, route wiring and connectors correctly, restore covers and grounding, and remove tools or loose parts.