Front

Which Section 608 certification covers small-appliance service?

Back

Type I certification covers servicing small appliances under EPA Section 608.

02
Front

What qualifies as a small appliance under the material's definition?

Back

A small appliance is factory-made, charged, and hermetically sealed, with no more than 55 pounds of refrigerant.

03
Front

What should a technician identify before servicing an appliance?

Back

Read the nameplate and service information to identify the refrigerant, charge, electrical requirements, and approved recovery equipment.

04
Front

What must be done before electrical inspection or repair?

Back

Disconnect power and verify the circuit is de-energized before electrical inspection or repair.

05
Front

What precautions apply when servicing an appliance with flammable refrigerant?

Back

Use equipment and procedures specifically approved for that refrigerant, and keep ignition sources away.

06
Front

What should be checked before suspecting a sealed-system problem?

Back

Check symptoms, controls, airflow, seals, condenser cleanliness, fans, and electrical connections before suspecting a sealed-system fault.

07
Front

May a technician intentionally vent refrigerant during service?

Back

EPA prohibits intentional venting during service; recover and contain refrigerant instead.

08
Front

When must refrigerant be recovered from a small appliance?

Back

Recover refrigerant with certified recovery and/or recycling equipment before opening a small appliance for service or disposing of it.

09
Front

What recovery percentage applies to equipment made before November 15, 1993?

Back

With recovery equipment manufactured before November 15, 1993, recover 80%80\% of the refrigerant.

10
Front

What percentage applies with later equipment when the compressor functions?

Back

With equipment manufactured on or after November 15, 1993, recover 90%90\% if the appliance compressor is functioning.

11
Front

What percentage applies with later equipment when the compressor does not function?

Back

With equipment manufactured on or after November 15, 1993, recover 80%80\% if the appliance compressor is not functioning.

12
Front

What vacuum level is an alternative to the small-appliance recovery percentages?

Back

As an alternative to the percentage routes, evacuate the appliance to 44 inches of mercury vacuum.