A technician is preparing to work in a poorly ventilated pit. The refrigerant has little odor, but a release could still create an asphyxiation hazard. True or false?
2 Safety and Preparation for Recovery Online Quiz Questions
Use this free practice quiz with 20 questions to review 2 Safety and Preparation for Recovery, test your knowledge, and prepare for your next test or exam.
Before choosing precautions for a recovery job, which approach best verifies the refrigerant’s hazards?
- A
Assume the refrigerant has the same hazards as the last one serviced.
- B
Check the equipment label and the refrigerant’s safety data sheet.
- C
Identify the refrigerant only by its odor.
- D
Choose PPE based only on the recovery machine’s brand.
A technician needs a container for refrigerant recovered from an appliance. Which container should the technician select?
- A
A disposable refrigerant supply cylinder.
- B
A suitable, approved refrigerant recovery cylinder.
- C
Any cylinder that can be connected to the hoses.
- D
A cylinder with damaged markings if its valve appears intact.
A technician must never heat a recovery cylinder to raise its pressure. True or false?
- A
True
- B
False
Which EPA Section number covers motor-vehicle air-conditioning service requirements?
A technician confirms that an appliance contains a flammable refrigerant. Which plan is appropriate before recovery begins?
- A
Use ordinary recovery equipment and avoid checking the appliance instructions.
- B
Use equipment and tools suitable for the refrigerant, follow instructions, and control ignition sources.
- C
Use a fan to direct vapor toward any nearby flame.
- D
Rely on the absence of an odor to determine whether ignition sources are safe.
A task assessment indicates a risk of a substantial liquid refrigerant release. Select all PPE practices supported for limiting eye and skin exposure.
- A
Wear safety glasses or goggles and gloves that protect against cold liquid refrigerant.
- B
Use a face shield when there is a risk of a substantial liquid release.
- C
Wear long sleeves, long pants, and sturdy footwear to help limit skin exposure.
- D
Use a respirator as a substitute for ventilation.
- E
Wear gloves only if the refrigerant is known to have a strong odor.
If respiratory protection is needed for a refrigerant-recovery task, under what type of program must it be selected and used?
During pre-use preparation, which actions help prevent cross-contamination or compatibility problems? Select all that apply.
- A
Confirm the refrigerant from the appliance nameplate and use an appropriate identifier when needed.
- B
Check that the recovery machine, hoses, fittings, and cylinder are compatible with the refrigerant and operating pressures.
- C
Use clean, dry equipment.
- D
Keep hoses capped when not in use and avoid transferring refrigerant, oil, or air between systems.
- E
Keep recovered refrigerant segregated by type and mark cylinders clearly.
- F
Mix unknown refrigerant into a cylinder of known refrigerant to reduce the number of containers.
- G
Use equipment that matches the pressure but is not confirmed compatible with the refrigerant.
A recovery cylinder is nearing its marked allowable fill during a job. What should the technician do?
- A
Continue until the cylinder looks full, then check its weight.
- B
Weigh it during recovery and stop before its marked allowable fill is exceeded.
- C
Fill it to the marked limit, then add a small amount to account for settling.
- D
Use pressure alone to determine whether the allowable fill has been reached.
A technician is deciding what evacuation level applies to a stationary refrigeration appliance. Which approach is appropriate?
- A
Apply one vacuum target to every appliance type.
- B
Use whichever vacuum target the recovery machine reaches most quickly.
- C
Check the EPA requirements that apply to the appliance and other relevant details.
- D
Choose a target based only on the refrigerant’s odor.
A significant refrigerant release occurs in a low area, and someone may still be inside. Explain what people should do and when an attempted rescue entry is inappropriate.
During recovery, a connection may release a substantial amount of liquid refrigerant. Which PPE choice best addresses the hazards described?
- A
Wear only safety glasses because liquid refrigerant presents no contact hazard.
- B
Wear suitable eye protection and cold-protective gloves, and add a face shield for the substantial-release risk.
- C
Use a respirator instead of eye and skin protection.
- D
Wear a face shield only if the refrigerant has a strong odor.
A technician proposes heating a recovery cylinder to raise its pressure before use. This is an acceptable preparation step.
- A
True
- B
False
A technician is selecting and setting up a cylinder for refrigerant recovery. Which procedure is appropriate?
- A
Use a disposable refrigerant supply cylinder if it is upright.
- B
Use any cylinder with a matching valve, even if its markings are out of date.
- C
Use a suitable, approved recovery cylinder after inspecting it, and secure it against tipping.
- D
Use a corroded cylinder if it is placed on a hand truck.
What kind of container should be used for unidentified or suspected contaminated refrigerant instead of mixing it with known refrigerant?
A significant refrigerant release occurs in a low, poorly ventilated area. A coworker may be inside. What is the safest response?
- A
Leave the area and do not enter the suspected oxygen-deficient space for rescue without appropriate training and equipment.
- B
Enter quickly if the refrigerant has little or no odor.
- C
Remain nearby and rely on a respirator as a substitute for ventilation.
- D
Try to ventilate the area by entering it without protective equipment.
Which EPA section has separate requirements for motor-vehicle air-conditioning service?
Before transporting a refrigerant recovery cylinder, fit the and use a suitable hand truck.
For stationary air-conditioning or refrigeration work that could release refrigerant, the generally applicable EPA technician certification is under Section .
Related study packs and tools
- Quiz
1 High- and Very-High-Pressure Refrigeration Systems
A medium-difficulty quiz on EPA pressure categories, refrigeration-cycle components, pressure behavior, and safety hazards.
EPA 608 Type IIUpdated - Flashcards
1 Refrigerant Types and Properties
Review how refrigerants transfer heat, how major refrigerant families differ, and how to select and handle them safely.
EPA 608 RefrigerantsUpdated - Study guide
1 Refrigerant Types and Properties
Learn how refrigerant families differ in applications, environmental effects, operating conditions, safety classifications, equipment compatibility, and handling requirements.
EPA 608 RefrigerantsUpdated - Quiz
2 Evacuation Levels and Verification
Practice determining appliance evacuation endpoints, measuring and verifying recovery, and checking recovery cylinders against the applicable requirements.
- Flashcards
3 Environmental Effects and Refrigerant Regulations
Learn how refrigerants affect ozone and climate, how regulations govern their use, and how to handle and select them responsibly.
EPA 608 RefrigerantsUpdated - Study guide
3 Environmental Effects and Refrigerant Regulations
Learn how refrigerants affect ozone and climate, how regulations govern their use and release, and what environmental and safety factors shape refrigerant selection.
EPA 608 RefrigerantsUpdated - Quiz
3 Safe Refrigerant Handling
A medium-difficulty quiz on applying safe refrigerant-handling practices, including hazard recognition, protective measures, leak response, and exposure response.
EPA 608 CoreUpdated - Flashcards
4 Safe Refrigerant Handling
Learn how to identify refrigerants, manage their hazards, recover and handle them safely, and prevent leaks.
EPA 608 RefrigerantsUpdated - Quiz
4 Safe Refrigerant Handling
A medium-difficulty quiz on identifying refrigerants, managing hazards, using equipment safely, preventing leaks, and handling cylinders.
EPA 608 RefrigerantsUpdated - Quiz
5 Chiller Service Practice and Verification
Practice chiller recovery, safety checks, endpoint verification, and service documentation. Follow equipment-specific procedures and applicable requirements.
EPA 608 Type IIIUpdated - Study guide
5 Chiller Service Practice and Verification
A practical framework for safely recovering refrigerant from chillers, verifying recovery and dehydration endpoints, troubleshooting problems, and documenting service work.
EPA 608 Type IIIUpdated - Quiz
5 Small Appliance Service and Compliance Workflows
A medium-difficulty quiz on identifying small appliances and applying Section 608 service, recovery, leak-check, and disposal practices.
EPA 608 Type IUpdated