During stationary air-conditioning service in the United States, it is acceptable to intentionally vent refrigerant if recovery would take too long.
3 Refrigerant Recovery Procedures Online Quiz Questions
Use this free practice quiz with 20 questions to review 3 Refrigerant Recovery Procedures, test your knowledge, and prepare for your next test or exam.
A technician is recovering refrigerant into an approved cylinder. Which practice best prevents overfilling?
- A
Fill the cylinder to its marked limit, then add a small amount to allow for later settling.
- B
Weigh the cylinder during recovery and stop before it reaches its marked fill limit.
- C
Estimate the amount by recovery time and check the cylinder weight only after the job.
- D
Continue filling until the cylinder pressure matches the system pressure.
What recovery method removes refrigerant as a gas to clear the charge remaining after accessible liquid has been recovered?
For a burned-out compressor or contaminated refrigerant, collect the refrigerant in a clearly identified and do not combine it with clean refrigerant.
Liquid entering a recovery machine too rapidly causes knocking. What should the operator do?
- A
Increase inlet flow so the machine clears the liquid faster.
- B
Switch off the machine and leave the valves open.
- C
Throttle the inlet as the machine manual directs.
- D
Vent a small amount of refrigerant to reduce the inlet pressure.
Recovering refrigerant from an appliance does not necessarily clean or purify the refrigerant.
- A
True
- B
False
Which setup practices are appropriate for refrigerant recovery? Select all that apply.
- A
Use a recovery machine approved for the refrigerant being handled.
- B
Use one cylinder for different refrigerants if it is weighed carefully.
- C
Use a separate, properly identified cylinder for each refrigerant.
- D
Monitor the cylinder weight throughout recovery.
- E
Use the same hose and cylinder-port arrangement for every recovery machine.
After the required level is reached, the system valves are closed as directed and pressure is allowed to stabilize. A pressure rise may indicate refrigerant remains in or .
Under the stated EPA leak exception, leaking sections must be brought to the lowest attainable pressure, not above what pressure? Enter the value in psig.
A technician is handling a low-pressure appliance during a non-major repair that will not be followed by evacuation to the atmosphere. Under the specific EPA rule described, what must happen before the appliance is opened?
- A
Open the appliance directly because low-pressure systems do not require recovery.
- B
For the specified repair situation, pressurize the appliance to 0 psig before opening it.
- C
Pressurize the appliance to 0 psig only after opening it.
- D
Use the push-pull method in every case, regardless of the appliance or repair.
Which statements correctly describe liquid push-pull recovery? Select all that apply.
- A
It transfers accessible bulk liquid using pressure and a siphon effect.
- B
It is suitable for every system and removes all remaining vapor.
- C
It requires an appropriate system layout and enough accessible liquid.
- D
A siphon can continue after the machine is switched off, so valves must be closed as directed.
- E
It eliminates the need to monitor cylinder weight.
An appliance contains 200 lb of refrigerant and is classified as medium-pressure. The recovery equipment was manufactured on or after November 15, 1993. What evacuation level applies?
- A
4 in. Hg vacuum
- B
15 in. Hg vacuum
- C
25 mm Hg absolute
- D
0 in. Hg vacuum
Describe a safe recovery sequence for a normally charged system when accessible liquid can be recovered. Include how the technician should handle the remaining charge and verify completion.
After recovering accessible liquid from a system, which method is used to remove the remaining refrigerant as gas?
- A
Use liquid push-pull to remove all refrigerant, including the remaining vapor.
- B
Use vapor recovery to remove the remaining refrigerant as gas.
- C
Stop recovery once accessible liquid has been transferred.
- D
Open the appliance after switching off the recovery machine.
A technician must recover two different refrigerants. Which cylinder practice is appropriate?
- A
Use one cylinder for all refrigerants if it is large enough.
- B
Mix refrigerants only when both are clean.
- C
Use a separate, properly identified cylinder for each refrigerant.
- D
Use an unmarked cylinder if the refrigerant is later tested.
Liquid push-pull transfers accessible bulk liquid, but it does not remove the refrigerant vapor that remains in the system.
- A
True
- B
False
During recovery, liquid entering the machine causes knocking. What should the technician do?
- A
Throttle the inlet as the machine manual directs.
- B
Increase liquid flow so the machine clears it faster.
- C
Close all valves and leave liquid trapped between them.
- D
Switch off the machine but leave the liquid path open.
How should a technician manage cylinder filling during refrigerant recovery?
- A
Estimate the amount transferred from the machine's run time.
- B
Stop weighing the cylinder once liquid transfer begins.
- C
Fill the cylinder to its marked limit, then allow it to warm.
- D
Monitor cylinder weight and stop before its marked fill limit.
An appliance contains 250 lb of refrigerant and is in the high-pressure category. What evacuation level applies when the recovery equipment was manufactured on or after November 15, 1993?
For a low-pressure appliance undergoing a qualifying non-major repair that is not followed by evacuation to the atmosphere, to what pressure must it be pressurized before opening?
Related study packs and tools
- Quiz
1 High- and Very-High-Pressure Refrigeration Systems
A medium-difficulty quiz on EPA pressure categories, refrigeration-cycle components, pressure behavior, and safety hazards.
EPA 608 Type IIUpdated - Study guide
1 Refrigerant Types and Properties
Learn how refrigerant families differ in applications, environmental effects, operating conditions, safety classifications, equipment compatibility, and handling requirements.
EPA 608 RefrigerantsUpdated - Quiz
2 Evacuation Levels and Verification
Practice determining appliance evacuation endpoints, measuring and verifying recovery, and checking recovery cylinders against the applicable requirements.
- Study guide
3 Environmental Effects and Refrigerant Regulations
Learn how refrigerants affect ozone and climate, how regulations govern their use and release, and what environmental and safety factors shape refrigerant selection.
EPA 608 RefrigerantsUpdated - Quiz
3 Safe Refrigerant Handling
A medium-difficulty quiz on applying safe refrigerant-handling practices, including hazard recognition, protective measures, leak response, and exposure response.
EPA 608 CoreUpdated - Quiz
4 Evacuation and Dehydration Procedures
A quiz on safe evacuation, dehydration, and vacuum verification for refrigeration circuits.
EPA 608 Type IIIUpdated - Quiz
4 Refrigerant Recovery and Cylinder Handling
A medium-difficulty quiz on safe refrigerant recovery, cylinder handling, and the differences among recovery, evacuation, and charging.
EPA 608 Type IIUpdated - Flashcards
4 Safe Refrigerant Handling
Learn how to identify refrigerants, manage their hazards, recover and handle them safely, and prevent leaks.
EPA 608 RefrigerantsUpdated - Quiz
4 Safe Refrigerant Handling
A medium-difficulty quiz on identifying refrigerants, managing hazards, using equipment safely, preventing leaks, and handling cylinders.
EPA 608 RefrigerantsUpdated - Quiz
5 Chiller Service Practice and Verification
Practice chiller recovery, safety checks, endpoint verification, and service documentation. Follow equipment-specific procedures and applicable requirements.
EPA 608 Type IIIUpdated - Study guide
5 Chiller Service Practice and Verification
A practical framework for safely recovering refrigerant from chillers, verifying recovery and dehydration endpoints, troubleshooting problems, and documenting service work.
EPA 608 Type IIIUpdated - Quiz
5 Small Appliance Service and Compliance Workflows
A medium-difficulty quiz on identifying small appliances and applying Section 608 service, recovery, leak-check, and disposal practices.
EPA 608 Type IUpdated