Timedora

Pressure and Hydrostatics

Builds from pressure and hydrostatic balance to pressure measurement with manometers and forces on submerged surfaces.

at Rest and with Depth

at rest

measures the normal force per unit area:

p=F⊥A.p=\frac{F_\perp}{A}.

The subscript indicates that only the component perpendicular to the surface contributes. is a scalar: it has magnitude but no direction. In a fluid at rest, at a point is equal in every direction, while the force exerted on a surface is perpendicular to that surface. A static fluid cannot sustain shear stress.

readings depend on their reference. is measured from a perfect vacuum; is measured relative to local atmospheric . They are related by

pabs=pg+patm.p_{\mathrm{abs}}=p_{\mathrm{g}}+p_{\mathrm{atm}}.

Thus, zero corresponds to atmospheric .

Why increases with depth

A fluid layer supports the weight of the fluid above it, so rises downward. For a stationary fluid with constant density, at depth hh below a surface where is p0p_0,

p=p0+ρgh,pg=ρghp=p_0+\rho gh, \qquad p_{\mathrm{g}}=\rho gh

when the surface is atmospheric. Here ρ\rho is density and gg is gravitational acceleration. Equivalently, if vertical coordinate zz is positive upward, hydrostatic balance is dp/dz=−ρgdp/dz=-\rho g. If density varies appreciably with height, integrate this relation using density as a function of height rather than assuming it is constant. Constant density is usually a good approximation for liquids over modest depth ranges.

For example, in water at 2 m depth, using ρ=1000 kg/m3\rho=1000\,\text{kg/m}^3 and g=9.81 m/s2g=9.81\,\text{m/s}^2:

pg=(1000)(9.81)(2)=19620 Pa≈19.6 kPa.p_{\mathrm{g}}=(1000)(9.81)(2)=19620\,\text{Pa}\approx19.6\,\text{kPa}.

This is the ; the is about 19.6 kPa plus local atmospheric .

Depth—not container shape—sets the in this model. Therefore, points at the same elevation in the same connected, stationary fluid have equal , even if the container’s shape differs.

Reading with a

Track as you move through the tube

A determines a difference from the liquid-column height. In a U-tube, pressures at the same elevation in the same continuous fluid are equal. To compare pressures along a path through the fluid, use two rules:

  • Moving down by a vertical distance Δh\Delta h adds ρgΔh\rho g\Delta h.

  • Moving up by that distance subtracts ρgΔh\rho g\Delta h.

For a simple open-tube containing one liquid of density ρm\rho_m, with one side connected to a source and the other open to the atmosphere, define the signed level difference Δh\Delta h as positive when the liquid level on the source side is lower than on the open side. Then

psource−patm=ρmgΔh.p_{\mathrm{source}}-p_{\mathrm{atm}}=\rho_m g\Delta h.

The magnitude comes from the height difference; the sign follows from which side has the higher liquid level. If the source pushes the liquid down on its side, its is positive. A level difference can also indicate below atmospheric , giving negative .

Worked example: water

For a water with a 0.20 m level difference, use ρm=1000 kg/m3\rho_m=1000\,\text{kg/m}^3 and g=9.81 m/s2g=9.81\,\text{m/s}^2:

∣psource−patm∣=(1000)(9.81)(0.20)=1962 Pa≈1.96 kPa.|p_{\mathrm{source}}-p_{\mathrm{atm}}| =(1000)(9.81)(0.20) =1962\,\text{Pa}\approx1.96\,\text{kPa}.

This calculation gives the -difference magnitude. Assign a positive or negative sign only after identifying which side has the higher liquid level and whether the source is above or below atmospheric . For a with several fluids, apply the same up/down steps to each segment using that segment’s density.

Resultant Forces on Submerged Surfaces

From distribution to one

acts normal to an immersed surface at every point. For a small area element dAdA, the force magnitude is

dF=p dA.dF=p\,dA.

The total force is found by integrating across the distribution. For a plane area AA in a liquid open to the atmosphere, the resultant gauge force is

FR=ρghˉA,F_R=\rho g\bar{h}A,

where hˉ\bar{h} is the depth of the area’s centroid. This is equivalent to multiplying the at the centroid by the area. The force acts perpendicular to the plane. This gauge-force calculation gives the net force due to the liquid when the other side is exposed to the same atmospheric ; use absolute pressures when calculating forces on both sides separately.

The resultant’s magnitude can be calculated using the centroid depth, but its line of action is generally not through the centroid. When depth varies across the plane, is greater at greater depth, so the resultant generally acts lower, at the . If the entire plane is at one depth, is uniform and the resultant acts through the centroid.

Worked example: a vertical rectangular gate

For a vertical rectangle of width bb and height HH, with its top at the free surface, increases linearly from zero at the top to its greatest value at the bottom. The distribution is triangular, giving

FR=12ρgbH2,hCP=2H3,F_R=\frac{1}{2}\rho g bH^2, \qquad h_{CP}=\frac{2H}{3},

where hCPh_{CP} is measured down from the surface.

For a water gate 2 m wide and 3 m high, with its top at the surface:

FR=12(1000)(9.81)(2)(32)=88290 N≈88.3 kN.F_R=\tfrac12(1000)(9.81)(2)(3^2) =88290\,\text{N}\approx88.3\,\text{kN}.

Its is at 2H/3=22H/3=2 m below the surface—one-third of the gate’s height above its bottom. The force is therefore not applied at the gate’s geometric center, even though the centroid depth is used to calculate the resultant’s magnitude.