Timedora

Air Pollution Prevention and Control

A practical guide to preventing emissions, matching control technologies to pollutants, and maintaining effective air-pollution controls.

Start at the Source

From a source to the surrounding air

Air pollutants can come from point sources, such as boilers and industrial stacks, or diffuse sources, such as vehicles, construction, and evaporating solvents. Once released, wind and atmospheric mixing transport and dilute pollutants. Chemical reactions can also form secondary pollutants, while deposition moves pollutants from air to land or water.

Because wind and mixing vary, dilution is not a dependable substitute for reducing emissions. Cutting emissions at the source is generally more reliable. Planning also needs to account for where a source is located, local air quality and meteorology, pollutant properties, engineering requirements, costs, and possible side effects of control.

Prevent pollution before it forms

Pollution prevention, or , means reducing or eliminating pollution before it is created. Where feasible, it is preferable to treating or disposing of pollution after it forms. Approaches include switching to lower-volatility materials, cleaner fuels, or less-contaminated feedstocks; improving processes and equipment; maintaining seals and valves and using closed systems to prevent leaks and evaporation; reducing dust at its source; and recovering and reusing materials when practical.

These steps can reduce both emissions and the amount of material that control equipment must handle. They do not always remove the need for add-on controls: emissions may remain, or stringent limits may apply.

Removing Particles from Gas

Particulate-control devices
DeviceHow it worksRole and considerations
Settling chamberSlows gas so gravity removes large particles.Simple; inefficient for fine particles; may be a precleaner.
CycloneSpins gas; inertia drives particles to the walls and into a hopper.Often removes larger, abrasive particles upstream of a more efficient device.
Fabric filter (baghouse)Gas passes through fabric; particles collect on the fabric and dust layer, which is periodically cleaned.Effective for fine PM in many applications; attend to temperature, moisture, dust, filter condition, and dust handling.
Electrostatic precipitator (ESP)Charges particles and attracts them to oppositely charged collection surfaces.Handles large gas flows; removal is by rapping or washing; performance partly depends on particle electrical properties.
Wet scrubberContacts particles with liquid droplets, which are then separated from the gas.Can also control some soluble gases; produces wastewater or slurry that must be managed.
Comparison of five particulate-control devices and their typical roles.

Match the device to the particles and process

Each device separates particulate matter from a gas stream by a different mechanism. A settling chamber slows the gas so gravity can remove larger particles; it is simple, but not effective for fine particles, so it may be used as a precleaner. A cyclone spins the gas, using particle inertia to drive particles toward the walls and into a hopper. It commonly removes larger, abrasive particles before a more efficient collector.

A fabric filter collects particles on fabric and on the dust layer that builds up there, then periodically cleans the filter. Its performance requires attention to temperature, moisture, dust characteristics, and filter condition. An electrostatic precipitator charges particles and attracts them to oppositely charged surfaces; collected material is removed by rapping or washing, and performance partly depends on the particles’ electrical properties. A wet scrubber brings particles into contact with liquid droplets and separates the droplets from the gas. Some designs also control soluble gases, but the resulting wastewater or slurry needs management.

A cyclone followed by a baghouse or ESP illustrates : the cyclone first removes larger particles, reducing the load on the final collector. A wet device may be favored for sticky or combustible dust, but water use, corrosion, and wastewater treatment must be considered. In every case, captured particulate material still has to be safely removed, reused, or disposed of.

Controlling Gaseous Pollutants

Gaseous-pollutant control methods
MethodWhat happensConsiderations
AbsorptionGas transfers into a liquid; it may react or be recovered.Wet flue-gas desulfurization uses an alkaline reagent for SO₂ and produces a liquid or solid by-product.
AdsorptionGas molecules attach to a solid surface, commonly activated carbon.Regenerate or replace adsorbent as it approaches capacity; regeneration may allow recovery.
CondensationCooling causes vapors to condense into liquid.Useful when vapor concentration and operating conditions make condensation practical.
OxidationCombustible pollutants, including many VOCs, react with oxygen, generally forming carbon dioxide and water.Thermal and catalytic oxidizers use heat; catalysts allow lower-temperature oxidation but can be affected by contaminants. Flares serve certain combustible gas streams.
Selective catalytic reduction (SCR)A reducing agent, commonly ammonia, and a catalyst convert NOₓ primarily to nitrogen and water.Operation is affected by temperature and ammonia slip.
The methods differ in whether they transfer pollutants, condense vapors, or chemically transform pollutants.

Transfer, recover, or transform

Gaseous-pollutant controls work by moving a pollutant into another medium, condensing it, or chemically changing it. The table compares these mechanisms; the examples below clarify what happens to the pollutant and what must be considered afterward.

In , a gas transfers into a liquid. The liquid may react with the pollutant or be treated to recover it. For example, wet flue-gas desulfurization uses an alkaline reagent to and react with sulfur dioxide (SO₂); it produces a liquid or solid by-product. By contrast, attaches gas molecules to a solid surface, commonly activated carbon. As the adsorbent approaches its capacity, it must be regenerated or replaced; regeneration may allow pollutant recovery.

Condensation cools a gas stream until vapors condense into a liquid that may be recoverable. It is useful when the vapor concentration and operating conditions make condensation practical. Oxidation reacts combustible pollutants, including many volatile organic compounds (VOCs), with oxygen, generally forming carbon dioxide and water. Thermal and catalytic oxidizers use heat; a catalyst permits oxidation at a lower temperature but can be affected by contaminants. Flares are used for certain combustible gas streams.

Selective catalytic reduction () injects a reducing agent, commonly ammonia, into flue gas and passes the mixture over a catalyst. The process converts nitrogen oxides (NOₓ) primarily to nitrogen and water. Temperature and ammonia slip affect operation. The mechanisms therefore differ not only in how they act on a pollutant, but also in their operating needs and the residuals or materials that require management.

, Selection, and Reliable Operation

is not the same as treatment

VOC control commonly depends on two linked steps. Hoods or enclosures vapors and direct them to a control device; the device then treats the captured stream. Overall performance depends on both how much pollution is captured and how effectively the device treats what it receives. Even a highly efficient treatment device cannot control vapors that escape .

Select for the actual emission stream

Begin with the source and the stream it produces: identify the pollutant and its concentration, particle size where relevant, gas flow, temperature, humidity, pressure, and variability. Then compare the required performance with the control’s reliability, energy and water needs, installation and operating costs, maintenance demands, worker safety, and secondary wastes. This makes control selection a matter of matching a technology to both the emissions and the conditions in which it must operate.

Keep the system working—and manage what it collects

Equipment must be operated and maintained as designed. Blocked ducts, damaged filter bags, poor gas distribution, worn seals, depleted adsorbent, or inadequate reagent supply can reduce performance. Monitoring operating conditions and inspecting equipment can help identify problems before they cause sustained emissions.

Captured pollutants do not simply disappear. Dust, spent adsorbent, scrubber liquid, and reaction products need appropriate recovery or disposal. A reliable control strategy therefore considers not only what leaves the stack, but also the operation of the equipment and the safe handling of its residuals.

  • : A source that releases pollutants from a distinct, identifiable location, such as a boiler or industrial stack.

  • : Pollution released across many locations or activities rather than from one distinct point.

  • : Solid particles and liquid droplets suspended in a gas stream.