Timedora
Free Online Flashcard Deck

2 Type I: Small Appliances Free Online FlashCards

Study 2 Type I: Small Appliances with 12 free online flashcards. Review key terms, definitions, and concepts with this interactive flashcard deck.

12 cards
01
Front

What qualifies as a Type I small appliance?

Back

A small appliance is factory-manufactured, factory-charged, and hermetically sealed, with 5 pounds or less of refrigerant. Examples include household refrigerators, window air conditioners, dehumidifiers, and water coolers.

02
Front

What is self-contained recovery equipment?

Back

Self-contained, or active, recovery equipment removes refrigerant without relying on the appliance’s components.

03
Front

What must be done before opening a small appliance for service?

Back

Recover the refrigerant using the applicable method before opening a small appliance for service.

04
Front

What recovery percentage applies to equipment made before November 15, 1993?

Back

For recovery equipment manufactured before November 15, 1993, recover 80% of the refrigerant, regardless of compressor condition.

05
Front

Why might a technician attach a solderless access fitting?

Back

A solderless access fitting can be attached to process tubing to connect recovery equipment when the appliance lacks permanent service valves.

06
Front

What should be done with a solderless access fitting when service is complete?

Back

At the end of service, remove solderless access fittings, restore the sealed system appropriately, and check for leaks.

07
Front

How should a working compressor be used during passive recovery?

Back

When using system-dependent recovery, operate the appliance’s functional compressor to help move refrigerant toward the recovery connection.

08
Front

Which refrigerant is a likely substitute for older R-12 applications?

Back

R-134a is a likely substitute to recognize for older R-12 applications.

09
Front

Why should refrigerants not be exposed to high temperatures?

Back

Avoid exposing refrigerants to high temperatures; decomposition can produce hazardous substances. Never use an open flame to heat an appliance.

10
Front

What is system-dependent recovery equipment?

Back

System-dependent, or passive, recovery equipment relies on appliance components, such as a working compressor, to move refrigerant.

11
Front

What recovery percentage applies to newer equipment with a working compressor?

Back

For equipment manufactured on or after November 15, 1993, recover 90% when the appliance compressor is functional.

12
Front

What recovery percentage applies to newer equipment with a failed compressor?

Back

For equipment manufactured on or after November 15, 1993, recover 80% when the appliance compressor is not functional.