2 Type I: Small Appliances

Learn how Type I small appliances are defined, how to recover their refrigerant under different equipment and compressor conditions, and what service and safety procedures apply.

What qualifies as a

A is fully manufactured, charged, and hermetically sealed at the factory, and contains 55 pounds or less of refrigerant. Type I certification covers servicing these appliances.

Examples include household refrigerators and freezers, window or portable air conditioners, dehumidifiers, vending machines, and drinking-water coolers.

Recovery equipment and required endpoints

Before opening a for service, recover its refrigerant using the applicable method. removes refrigerant without relying on the appliance’s components. relies on appliance components, such as a working compressor, to move refrigerant; passive recovery methods are included in Type I topics.

The required recovery endpoint depends on the recovery equipment’s manufacture date and whether the appliance compressor works:

  • Equipment manufactured before November 15, 1993: recover 80%80\%, regardless of compressor condition.

  • Equipment manufactured on or after November 15, 1993, with a functional compressor: recover 90%90\%.

  • Equipment manufactured on or after November 15, 1993, with a nonfunctional compressor: recover 80%80\%.

  • Alternatively, evacuate the appliance to a 4 in. Hg4\ \text{in. Hg} vacuum.

Follow the recovery equipment manufacturer’s instructions. The 44-inch-Hg-vacuum alternative is not a percentage of refrigerant recovered.

Appliance-specific recovery procedures

Small appliances often lack permanent service valves. A technician may attach a to the process tubing to connect recovery equipment. Remove solderless access fittings at the end of service, restore the sealed system appropriately, and check for leaks.

With a functional compressor, operate it when using system-dependent recovery so it helps move refrigerant through the circuit and toward the recovery connection.

With an inoperative compressor, passive recovery cannot rely on the appliance compressor. When using a system-dependent device, access both the high and low sides. Other recovery methods to know include controlled warming and sharply tapping the compressor, as well as using a vacuum pump with a non-pressurized recovery container. Use appropriate equipment and safe procedures; never use an open flame to heat an appliance.

Refrigerant identification and safety

Pressure and temperature readings can help identify a refrigerant and detect possible . Compare the readings with the correct pressure–temperature information. is a likely substitute to recognize for older R-12 applications.

Avoid exposing refrigerants to high temperatures: decomposition can produce hazardous substances.