Timedora
Free Practice Quiz Question List

2 Type I: Small Appliances Online Quiz Questions

Use this free practice quiz with 20 questions to review 2 Type I: Small Appliances, test your knowledge, and prepare for your next test or exam.

20 questions
01
True or false
1 point

True or false: Self-contained (active) recovery equipment relies on the appliance’s components to move refrigerant.

  1. A

    True

  2. B

    False

02
Choose one
1 point

Which unit meets the material’s definition of a Type I small appliance?

  1. A

    A field-assembled unit containing 6 pounds of refrigerant

  2. B

    A factory-sealed, factory-charged unit containing 4 pounds of refrigerant

  3. C

    A factory-sealed unit containing 8 pounds of refrigerant

  4. D

    A factory-charged unit that is not hermetically sealed

03
Written response
1 point

Which refrigerant is identified as a likely substitute to recognize for older R-12 applications?

04
Fill in the blank
1 point

A Type I small appliance contains of refrigerant.

05
True or false
1 point

True or false: When using system-dependent recovery on an appliance with a functional compressor, operate the compressor to help move refrigerant through the circuit.

  1. A

    True

  2. B

    False

06
Choose one
1 point

A small appliance has no permanent service valve. What is the purpose of attaching a solderless access fitting to its process tubing?

  1. A

    Replace the appliance compressor

  2. B

    Measure refrigerant temperature without a gauge

  3. C

    Connect recovery equipment to process tubing

  4. D

    Seal a leak without restoring the sealed system

07
Written response
1 point

Recovery equipment was manufactured on or after November 15, 1993, and the small appliance’s compressor works. If using the percentage endpoint, what percentage of refrigerant must be recovered?

08
Fill in the blank
1 point

When using a system-dependent recovery device on an appliance with an inoperative compressor, provide access to .

09
Choose all
1 point

Select all the items identified as examples of small appliances.

  1. A

    Household refrigerators and freezers

  2. B

    A field-assembled commercial refrigeration system

  3. C

    Dehumidifiers

  4. D

    Drinking-water coolers

  5. E

    Any system containing more than 5 pounds of refrigerant

10
Choose one
1 point

After using a solderless access fitting during service, which action best completes the work?

  1. A

    Leave the fitting in place as a permanent service valve

  2. B

    Remove the fitting, restore the sealed system appropriately, and check for leaks

  3. C

    Remove the fitting but leave the system unsealed

  4. D

    Check for leaks only if the appliance compressor is functional

11
Choose all
1 point

When using system-dependent recovery with an inoperative appliance compressor, select all the recovery procedures identified for this situation, including the access setup.

  1. A

    Access both the high and low sides

  2. B

    Use controlled warming

  3. C

    Sharply tap the compressor

  4. D

    Use a vacuum pump with a non-pressurized recovery container

  5. E

    Heat the appliance with an open flame

  6. F

    Rely on the inoperative appliance compressor to move refrigerant

12
True or false
1 point

True or false: Exposing refrigerants to high temperatures can cause decomposition that produces hazardous substances.

  1. A

    True

  2. B

    False

13
Choose one
1 point

Which option is the alternative recovery endpoint described in the material, rather than a percentage of refrigerant recovered?

  1. A

    Evacuate to 4% of atmospheric pressure

  2. B

    Recover 4 pounds of refrigerant

  3. C

    Evacuate the appliance to 4 in. Hg vacuum

  4. D

    Recover 4% of the refrigerant

14
Open ended
1 point

When checking an appliance’s refrigerant, explain what pressure and temperature readings can help you determine and what information you should compare them with.

15
Choose one
1 point

A technician is servicing an older appliance originally designed for R-12. Which refrigerant is identified as a likely substitute to recognize for this application?

  1. A

    R-22

  2. B

    R-134a

  3. C

    R-410A

  4. D

    R-404A

16
Choose one
1 point

A factory-manufactured, factory-charged, hermetically sealed unit contains exactly 5 pounds of refrigerant. Based on the Type I definition, which conclusion is correct?

  1. A

    It qualifies as a small appliance because it is factory-manufactured, charged, and sealed, and its charge does not exceed 5 pounds.

  2. B

    It does not qualify because small appliances must contain less than 5 pounds of refrigerant.

  3. C

    It does not qualify because a small appliance must have a permanent service valve.

  4. D

    It qualifies only if it is a household refrigerator or freezer.

17
Choose one
1 point

A technician selects system-dependent recovery equipment for a small appliance. Which description best explains how this equipment moves refrigerant?

  1. A

    It removes refrigerant without relying on any appliance components.

  2. B

    It operates only by evacuating the appliance to a vacuum endpoint.

  3. C

    It relies on appliance components to move refrigerant.

  4. D

    It is used only when the appliance contains more than 5 pounds of refrigerant.

18
Written response
1 point

Instead of meeting a percentage-recovery endpoint, a technician uses the stated vacuum alternative before opening a small appliance. What magnitude, in inches of mercury vacuum, must the appliance reach?

19
Choose one
1 point

A technician uses recovery equipment manufactured before November 15, 1993. Which percentage-recovery endpoint applies, regardless of the appliance compressor's condition?

  1. A

    Recover 90% if the appliance compressor works and 80% if it does not.

  2. B

    Recover 80% whether or not the appliance compressor works.

  3. C

    Recover 90% whether or not the appliance compressor works.

  4. D

    Recover 80% only if the appliance compressor does not work.

20
Written response
1 point

A small appliance has an inoperative compressor, and a technician is using a system-dependent recovery device. Which two sides must the technician access?