01
Front

What work does Type I certification cover?

Back

Type I certification covers technicians who maintain, service, or repair small appliances under EPA Section 608.

02
Front

What makes an appliance a small appliance under Section 608?

Back

It must be fully manufactured, charged, and hermetically sealed in a factory, and contain five pounds or less of refrigerant.

03
Front

Does exactly five pounds of refrigerant meet the charge limit?

Back

Yes. The charge limit includes exactly five pounds, as long as the appliance also meets the factory-manufacture, charging, and sealing requirements.

04
Front

Name examples of small appliances.

Back

Household refrigerators and freezers, window and portable air conditioners, dehumidifiers, vending machines, and drinking-water coolers are examples.

05
Front

When must refrigerant be recovered from a small appliance?

Back

Recover refrigerant with appropriate recovery equipment before opening a small appliance for service or disposing of it.

06
Front

What recovery percentage applies to equipment made before November 15, 1993?

Back

Equipment manufactured before November 15, 1993, requires 80% recovery, regardless of compressor condition.

07
Front

What recovery percentage applies to newer equipment with a functional compressor?

Back

Equipment made on or after November 15, 1993, requires 90% recovery when the compressor functions.

08
Front

What recovery percentage applies to newer equipment with a failed compressor?

Back

Equipment made on or after November 15, 1993, requires 80% recovery when the compressor is not functional.

09
Front

What vacuum level is an alternative to the recovery percentage?

Back

Instead of meeting the applicable recovery percentage, evacuate the appliance to 4 inches of mercury vacuum.

10
Front

How should a functional compressor be used with a passive recovery device?

Back

Operate the functional appliance compressor during recovery, following the passive device manufacturer’s instructions.

11
Front

Why does passive recovery from a failed-compressor appliance need access to both sides?

Back

A passive device cannot rely on a failed compressor to circulate refrigerant, so provide access to both the high and low sides.

12
Front

Where should access valves be installed when the compressor is inoperative?

Back

Install access valves on both the high side and the low side of the appliance circuit.