Timedora
Free Online Flashcard Deck

2 Type I: Small Appliances Free Online FlashCards

Study 2 Type I: Small Appliances with 12 free online flashcards. Review key terms, definitions, and concepts with this interactive flashcard deck.

12 cards
01
Front

What qualifies as a small appliance under Type I?

Back

A small appliance is factory-manufactured, charged, and hermetically sealed with 5 pounds or less of refrigerant.

02
Front

Name examples of Type I small appliances.

Back

Examples include household refrigerators and freezers, room air conditioners, dehumidifiers, vending machines, and drinking-water coolers.

03
Front

When does servicing a small appliance generally require Section 608 certification?

Back

A technician who services a small appliance and may open its refrigerant circuit generally needs Section 608 certification.

04
Front

What certification exception applies to small-appliance disposal?

Back

There is a federal certification exception for people recovering refrigerant from small appliances in the waste stream as part of disposal. Recovery and safe-disposal rules still apply.

05
Front

When must refrigerant be recovered from a small appliance?

Back

Recover refrigerant before opening the refrigerant circuit or disposing of the appliance.

06
Front

What percentage recovery applies to equipment made before November 15, 1993?

Back

For equipment manufactured before November 15, 1993, the percentage method requires 80% recovery, regardless of compressor condition.

07
Front

What percentage applies to newer equipment with a functioning compressor?

Back

For equipment manufactured on or after November 15, 1993, a functioning compressor requires 90% recovery under the percentage method.

08
Front

What percentage applies to newer equipment with an inoperative compressor?

Back

For equipment manufactured on or after November 15, 1993, an inoperative compressor requires 80% recovery under the percentage method.

09
Front

What evacuation level is an alternative to percentage recovery?

Back

As an alternative to the applicable percentage-recovery method, evacuate the appliance to 4 inches of mercury vacuum.

10
Front

How does self-contained recovery equipment move refrigerant?

Back

Self-contained, or active, equipment has its own means of moving refrigerant into a recovery container.

11
Front

What charge limit applies to system-dependent recovery equipment?

Back

System-dependent, or passive, equipment relies on the appliance compressor or system pressure. It is generally limited to appliances with a full charge of 15 pounds or less, unless permanently attached as a pump-out unit.

12
Front

With passive recovery and an inoperative compressor, which sides need access?

Back

Provide access to both the high and low sides so refrigerant trapped on either side can be recovered.