Timedora
Free Online Flashcard Deck

5 Universal Certification Practice and Review Free Online FlashCards

Study 5 Universal Certification Practice and Review with 12 free online flashcards. Review key terms, definitions, and concepts with this interactive flashcard deck.

12 cards
01
Front

Which equipment categories does Universal certification cover?

Back

Universal certification covers Core and all three equipment types: Type I, Type II, and Type III. The Core exam must be proctored.

02
Front

What is the environmental distinction between HFCs and ozone-depleting refrigerants?

Back

HFCs have zero ozone-depletion potential because they contain no chlorine, but some have high global-warming potential.

03
Front

What is Section 608's general rule on intentionally venting refrigerants?

Back

Section 608 generally prohibits intentionally venting refrigerants during service, repair, or disposal, with limited exceptions.

04
Front

What does recovering refrigerant mean?

Back

Recovering means removing refrigerant from equipment and storing it without necessarily processing it.

05
Front

What must generally happen before recovered refrigerant is transferred to a different owner?

Back

Recovered refrigerant transferred to a different owner generally must be reclaimed by an EPA-certified reclaimer.

06
Front

What gas should be used to pressure-test a refrigeration system?

Back

Use regulated nitrogen with appropriate protective equipment and pressure-relief protection. Never pressure-test with oxygen or compressed air.

07
Front

Why must a repaired system be evacuated before charging?

Back

Evacuate a repaired system before charging to remove air and moisture.

08
Front

What recovery level applies to a functional small-appliance compressor with post-1993 recovery equipment?

Back

The minimum recovery level is 90%90\%, or the appliance may be evacuated to 44 inches of mercury vacuum.

09
Front

Can system-dependent recovery equipment be used on a system with more than 1515 pounds of refrigerant?

Back

No. System-dependent recovery equipment may not be used on a system containing more than 1515 pounds of refrigerant.

10
Front

What evacuation level applies to a low-pressure appliance?

Back

The evacuation level is 25 mm Hg25\ \text{mm Hg} absolute, regardless of whether the appliance predates or postdates November 15, 1993.

11
Front

What is the maximum system pressure before removing oil from a stationary refrigeration appliance?

Back

Reduce system pressure to no greater than 5 psig5\ \text{psig} before removing oil, or drain the oil into a receiver that is then brought to that pressure.

12
Front

What does recycling refrigerant mean?

Back

Recycling cleans refrigerant for reuse, generally in equipment owned by the same person.