2 Type I: Small Appliances Online Quiz Questions

Use this free practice quiz with 20 questions to review 2 Type I: Small Appliances, test your knowledge, and prepare for your next test or exam.

20 questions
01
Fill in the blank
1 point

Before opening a small appliance’s refrigerant circuit or disposing of it, the refrigerant.

02
True or false
1 point

Under Section 608 terminology, recovery removes refrigerant and stores it in an external container; recovery alone does not require testing or processing the refrigerant.

  1. A

    True

  2. B

    False

03
Written response
1 point

What vacuum value, in inches of mercury, is an alternative to the applicable percentage-recovery method for a small appliance?

04
Choose one
1 point

Which appliance meets the Section 608 definition of a small appliance?

  1. A

    An appliance assembled and charged in the field with a 4-pound refrigerant charge

  2. B

    An appliance fully manufactured, charged, and hermetically sealed at the factory with a 5-pound refrigerant charge

  3. C

    An appliance fully manufactured and sealed at the factory with a 6-pound refrigerant charge

  4. D

    An appliance factory-sealed with a 5-pound charge but not charged until after installation

05
Choose one
1 point

A technician uses recovery equipment manufactured after November 15, 1993, and the appliance’s compressor functions. What percentage recovery is required under the percentage method?

  1. A

    80%

  2. B

    85%

  3. C

    90%

  4. D

    100%

06
Choose one
1 point

A technician plans to use system-dependent recovery equipment on an appliance with a 12-pound full charge. The equipment is not permanently attached as a pump-out unit. Is this use permitted?

  1. A

    No; system-dependent equipment is never allowed on small appliances.

  2. B

    Yes; its full charge is within the 15-pound limit.

  3. C

    No; the limit is 10 pounds unless the appliance has a functioning compressor.

  4. D

    Yes, but only if the appliance is permanently attached to the recovery device.

07
Choose one
1 point

A small appliance’s compressor functions, and a technician is using system-dependent recovery equipment. What should the technician do to help move refrigerant?

  1. A

    Operate the compressor to help move refrigerant.

  2. B

    Disable the compressor so the device can move refrigerant independently.

  3. C

    Open the refrigerant circuit and allow pressure to release before recovery.

  4. D

    Use only a self-contained recovery device, because system-dependent equipment cannot be used with a functioning compressor.

08
Choose all
1 point

A small appliance’s compressor is inoperative, and a technician is using system-dependent recovery equipment. Which two actions are appropriate recovery techniques?

  1. A

    Provide access to both the high and low sides.

  2. B

    Recover only from the low side because refrigerant cannot remain on the high side.

  3. C

    Consider warming the appliance to encourage refrigerant movement, when appropriate.

  4. D

    Release refrigerant from the high side to reduce pressure before recovery.

09
Choose all
1 point

Select all statements that accurately describe small-appliance recovery-device designs.

  1. A

    Self-contained equipment has its own means of moving refrigerant into a recovery container.

  2. B

    Self-contained equipment relies on the appliance’s compressor to move refrigerant.

  3. C

    System-dependent equipment relies on the appliance’s compressor or system pressure to move refrigerant.

  4. D

    System-dependent equipment always has its own means of moving refrigerant, independent of the appliance.

10
Fill in the blank
1 point

At the end of service, a temporary solderless access fitting should be when appropriate.

11
True or false
1 point

Federal mandatory leak-rate repair timelines apply to qualifying small appliances.

  1. A

    True

  2. B

    False

12
Written response
1 point

What type of permanently attached unit is an exception to the 15-pound limit for system-dependent recovery equipment?

13
Choose one
1 point

After servicing a sealed small-appliance system, when should a technician check for leaks in relation to charging or recharging?

  1. A

    Check for leaks only after the appliance has been charged.

  2. B

    Check for leaks only if the appliance uses a system-dependent recovery device.

  3. C

    Check for leaks before charging or recharging.

  4. D

    A leak check is unnecessary if temporary access fittings were used.

14
Open ended
1 point

A worker is recovering refrigerant from small appliances in the waste stream as part of disposal. Explain when Section 608 certification is generally required for small-appliance service, how this worker may qualify for the federal certification exception, and what obligations still apply.

15
Choose one
1 point

Which appliance meets the definition of a Type I small appliance?

  1. A

    A field-assembled unit containing 4 pounds of refrigerant

  2. B

    A unit fully manufactured, charged, and hermetically sealed at the factory with 5 pounds or less of refrigerant

  3. C

    A unit fully manufactured, charged, and hermetically sealed at the factory with more than 5 pounds of refrigerant

  4. D

    A unit fully manufactured and charged at the factory with 5 pounds or less of refrigerant, but not hermetically sealed

16
Choose one
1 point

A technician removes refrigerant from an appliance and stores it in an external container without testing or processing it. Which practice does this describe?

  1. A

    Removing refrigerant and testing it before storage

  2. B

    Processing refrigerant so it can be reused

  3. C

    Removing refrigerant and storing it in an external container

  4. D

    Releasing refrigerant after removing it from the appliance

17
Written response
1 point

What is the first date on which recovery equipment is classified as newer equipment for the percentage-recovery method?

18
Written response
1 point

What numerical evacuation endpoint, in inches of mercury vacuum, is permitted as an alternative to the percentage-recovery method? Enter the number only.

19
Choose one
1 point

A technician plans to use system-dependent recovery equipment on an appliance. Which condition makes this use permissible under the stated charge-size limit?

  1. A

    It may be used on an appliance with a full charge of 15 pounds or less, or when permanently attached as a pump-out unit.

  2. B

    It may be used only when the appliance contains exactly 15 pounds of refrigerant.

  3. C

    It may be used on any appliance if its compressor is functioning.

  4. D

    It may be used only if it has its own means of moving refrigerant into a recovery container.

20
True or false
1 point

Because a qualifying small appliance is below the federal mandatory leak-rate repair thresholds, a technician may intentionally vent its refrigerant.

  1. A

    True

  2. B

    False