Timedora
Free Online Flashcard Deck

1 Section 608 Certification and Environmental Rules Free Online FlashCards

Study 1 Section 608 Certification and Environmental Rules with 12 free online flashcards. Review key terms, definitions, and concepts with this interactive flashcard deck.

12 cards
01
Front

What equipment does Section 608 cover?

Back

Section 608 establishes the federal refrigerant-management program for stationary air-conditioning and refrigeration equipment.

02
Front

How does Section 609 differ from Section 608?

Back

Section 609 generally covers servicing motor vehicle air conditioners (MVACs); Section 608 applies to equipment within its own scope.

03
Front

When must a technician have Section 608 certification?

Back

A technician must hold the appropriate Section 608 certification before work reasonably expected to release refrigerant, such as connecting gauges or opening a refrigerant circuit.

04
Front

Who awards Section 608 certification, and do credentials expire?

Back

An EPA-approved certifying organization awards certification after the technician passes the relevant exam. EPA approves testing programs but does not issue certification cards, and credentials do not expire.

05
Front

When may an apprentice work without certification?

Back

An apprentice may work without certification only while closely and continually supervised by a certified technician.

06
Front

Which equipment does Type I certification cover?

Back

Type I covers servicing small appliances.

07
Front

Which equipment does Type II certification cover?

Back

Type II covers servicing or disposing of high- or very-high-pressure appliances, except small appliances and MVACs.

08
Front

Which equipment does Type III certification cover?

Back

Type III covers servicing or disposing of low-pressure appliances.

09
Front

What equipment categories does Universal certification cover?

Back

Universal certification covers all three equipment categories: small appliances, high- or very-high-pressure appliances, and low-pressure appliances.

10
Front

What must technicians do with refrigerant during service or disposal?

Back

During servicing, repair, or disposal, technicians must recover rather than knowingly release refrigerant, using required recovery or recycling equipment and applicable procedures.

11
Front

What does prohibited refrigerant venting mean?

Back

Venting is knowingly releasing refrigerant to the atmosphere during maintenance, service, repair, or disposal. Deliberately purging a covered charge instead of recovering it is prohibited.

12
Front

What kind of release may qualify as de minimis?

Back

Small releases associated with good-faith recovery or recycling efforts, such as incidental releases when connecting or disconnecting service hoses, may qualify as de minimis.