3 Refrigerant Handling and Service Procedures Online Quiz Questions

Use this free practice quiz with 20 questions to review 3 Refrigerant Handling and Service Procedures, test your knowledge, and prepare for your next test or exam.

20 questions
01
Choose one
1 point

A technician plans to sell recovered refrigerant to a different owner for reuse. Which handling step is required before the sale?

  1. A

    Recover it, because recovery alone makes it suitable for sale to another owner.

  2. B

    Recycle it, because cleaning makes it suitable for sale to another owner.

  3. C

    Reclaim it, because it must meet purity specifications verified by an EPA-certified reclaimer.

  4. D

    Store it, because refrigerant may be transferred without further processing.

02
True or false
1 point

A technician may intentionally vent refrigerant during service as long as the appliance is being repaired in good faith.

  1. A

    True

  2. B

    False

03
Written response
1 point

A small appliance contains five pounds or less of refrigerant, and its compressor is functional. What minimum recovery percentage must the recovery equipment achieve?

04
Fill in the blank
1 point

Before removing oil from an appliance or isolated section, reduce its pressure to psig or less.

05
Choose all
1 point

Select all methods that can help locate a refrigerant leak.

  1. A

    An appropriate leak detector

  2. B

    A pressure-decay test by itself

  3. C

    Bubble solution

  4. D

    Ultrasonic detection

06
True or false
1 point

Section 608 leak-repair requirements apply to appliances containing only substitute refrigerants such as HFCs.

  1. A

    True

  2. B

    False

07
Choose one
1 point

Before opening a medium-pressure appliance charged with 200 pounds or more, what evacuation level applies if it was manufactured on or after November 15, 1993?

  1. A

    4 in. Hg vacuum

  2. B

    10 in. Hg vacuum

  3. C

    15 in. Hg vacuum

  4. D

    25 mm Hg absolute

08
Written response
1 point

What is the name of the test that checks a repair after the appliance returns to normal operating conditions?

09
Fill in the blank
1 point

For a qualifying Section 608 leak, the owner or operator generally must repair the leak or develop a retrofit or retirement plan within days.

10
Choose all
1 point

When disposing of an appliance containing 5–50 pounds of refrigerant, select all information that must be included in the required records.

  1. A

    The recovery location and date

  2. B

    The refrigerant type

  3. C

    The technician's total labor hours for the service call

  4. D

    Monthly recovered quantities

  5. E

    Quantities transferred for reclamation or destruction

11
Choose one
1 point

A pressure or vacuum decay test shows that a system is leaking. What conclusion can the technician draw from that test alone?

  1. A

    It identifies the precise point of leakage.

  2. B

    It can indicate that the system is leaking, but does not by itself locate the leak.

  3. C

    It verifies that a repair passed the follow-up test.

  4. D

    It determines whether recovered refrigerant meets reclamation purity specifications.

12
Open ended
1 point

A leak prevents a technician from reaching the required evacuation level before opening an appliance. Explain how the technician should handle the leaking and non-leaking portions.

13
Choose one
1 point

A technician is preparing to service an appliance. Which approach meets the general certification and equipment requirements?

  1. A

    Certification is needed only for refrigerant sales, and any recovery equipment may be used.

  2. B

    Certification for one appliance type covers all appliance types, and manufacturer instructions are optional.

  3. C

    The technician must be certified for the appliance type serviced, use appropriate certified recovery equipment, and follow its instructions.

  4. D

    Only the equipment manufacturer must be certified; technicians may service any appliance type.

14
True or false
1 point

For a qualifying minor repair that does not involve evacuating the appliance to the environment, low-pressure equipment must be brought to 0 psig before opening.

  1. A

    True

  2. B

    False

15
Choose one
1 point

A technician is recovering refrigerant from a small appliance containing no more than five pounds. Its compressor is not functional. What recovery percentage must the equipment achieve to satisfy the applicable recovery requirement?

  1. A

    70%

  2. B

    75%

  3. C

    80%

  4. D

    90%

16
Written response
1 point

Before removing oil from an appliance, a technician chooses to reduce the pressure in the appliance itself. What is the maximum pressure allowed? Enter the value in psig.

17
Written response
1 point

A technician is preparing to open a high-pressure appliance with a charge of 200 pounds or more. It was manufactured on or after November 15, 1993. What evacuation level is required? Enter the reading in inches of mercury vacuum.

18
Choose one
1 point

After repairing a covered leak, a technician has added refrigerant and returned the appliance to normal operating conditions. Which test checks that the repair remains effective at this stage?

  1. A

    A leak inspection

  2. B

    An initial verification test

  3. C

    A follow-up verification test

  4. D

    A pressure or vacuum decay test used to locate the leak

19
Choose one
1 point

A commercial refrigeration appliance contains a full charge of 60 pounds of an ozone-depleting refrigerant and has an annualized leak rate of 22%. Under the Section 608 rules described in the material, what is the correct conclusion?

  1. A

    No corrective action is required because commercial refrigeration has a 30% threshold.

  2. B

    No corrective action is required because Section 608 leak-repair rules cover only HFC substitutes.

  3. C

    Corrective action is required because the charge and leak rate exceed the applicable Section 608 criteria.

  4. D

    Corrective action is required only if the annualized leak rate exceeds 30%.

20
Choose one
1 point

An appliance otherwise uses an HFC covered by the separate AIM Act leak-repair program. Which appliance category is exempt from those leak-repair provisions?

  1. A

    All industrial process refrigeration appliances

  2. B

    All commercial refrigeration appliances

  3. C

    Residential and light-commercial air-conditioning and heat-pump appliances

  4. D

    Every appliance with a full charge under 50 pounds