Timedora
Free Practice Quiz Question List

9 Universal Certification Practice Exam Online Quiz Questions

Use this free practice quiz with 20 questions to review 9 Universal Certification Practice Exam, test your knowledge, and prepare for your next test or exam.

20 questions
01
True or false
1 point

As a general rule, intentionally releasing refrigerant to the atmosphere while servicing stationary refrigeration equipment is prohibited, subject to limited exceptions.

  1. A

    True

  2. B

    False

02
Fill in the blank
1 point

In the stratosphere, CFCs can release when broken down by .

03
Choose all
1 point

Select all characteristics that belong to the general Section 608 definition of a small appliance.

  1. A

    It is factory-manufactured.

  2. B

    It is charged with refrigerant.

  3. C

    It is hermetically sealed.

  4. D

    It contains five pounds or less of refrigerant.

  5. E

    It contains more than five pounds of refrigerant.

04
Written response
1 point

What minimum percentage of refrigerant must EPA-certified recovery equipment be capable of recovering from a small appliance with a functioning compressor?

05
Choose one
1 point

A technician is about to add a different refrigerant to a recovery cylinder that already contains refrigerant. What is the principal reason to avoid doing this?

  1. A

    Mixing guarantees that the refrigerants will be easier to reclaim.

  2. B

    The mixture can be difficult or impossible to identify and reclaim properly.

  3. C

    Mixing always lowers cylinder pressure to zero.

  4. D

    All refrigerants are required to be mixed before shipment.

06
Choose all
1 point

A technician is preparing to pressure-test a refrigeration system. Select all the appropriate practices.

  1. A

    Use dry nitrogen.

  2. B

    Use a regulator.

  3. C

    Use suitable pressure controls.

  4. D

    Use oxygen to reach the test pressure more quickly.

  5. E

    Use compressed air if the system is empty.

07
Written response
1 point

Before removing oil from a refrigeration appliance, reduce its refrigerant pressure to no greater than what value?

08
Fill in the blank
1 point

After a low-pressure appliance reaches its required recovery vacuum, wait briefly and check whether pressure ; this may indicate refrigerant remains in liquid or oil.

09
True or false
1 point

During chiller evacuation, circulating or removing water helps prevent water in the tubes from freezing as system pressure and temperature fall.

  1. A

    True

  2. B

    False

10
Open ended
1 point

During recovery, a technician finds a leak and cannot reach the specified evacuation level without substantially contaminating the recovered refrigerant. What general procedure should the technician follow?

11
Choose one
1 point

A technician is deciding whether to add refrigerant beyond a recovery cylinder's permitted fill limit. Why must the technician stay within that limit?

  1. A

    Warming refrigerant expands it, and an overfilled cylinder can develop dangerous pressure.

  2. B

    The cylinder will lose its color code.

  3. C

    The refrigerant will become a noncondensable gas.

  4. D

    Recovery equipment cannot detect an overfilled cylinder.

12
True or false
1 point

When charging a zeotropic refrigerant blend, liquid charging may be needed to reduce fractionation and preserve the blend's intended composition; the technician should follow the refrigerant and equipment instructions.

  1. A

    True

  2. B

    False

13
Choose one
1 point

A technician needs to pressure-test a refrigeration system. Which gas should the technician use with suitable pressure controls?

  1. A

    Oxygen

  2. B

    Compressed air

  3. C

    Dry nitrogen with a regulator

  4. D

    Propane

14
Written response
1 point

When ultraviolet radiation breaks down CFCs in the stratosphere, which element is released and contributes to ozone destruction?

15
Choose one
1 point

A technician removes refrigerant from equipment, cleans some for reuse, and sends some for processing and verification against a purity standard. Which option correctly identifies these three activities?

  1. A

    Recovery removes refrigerant; recycling cleans it for reuse; reclamation processes and verifies it to a specified purity standard.

  2. B

    Recovery and reclamation both mean venting; recycling means storing refrigerant.

  3. C

    Recycling verifies refrigerant to the same standard as reclamation.

  4. D

    Reclamation means a technician uses a filter-drier alone.

16
Written response
1 point

A factory-made, charged, hermetically sealed appliance is being classified under the Section 608 small-appliance definition. What is the maximum refrigerant charge, in pounds, for it to meet that definition?

17
Choose one
1 point

A technician has refrigerant left over from two different systems. Why should the technician keep the refrigerants in separate recovery cylinders?

  1. A

    Mixing guarantees that the refrigerants become nonflammable.

  2. B

    The mixture can be difficult or impossible to identify and reclaim properly.

  3. C

    Mixing reduces the cylinder pressure to zero.

  4. D

    All refrigerants must be mixed before shipment.

18
Choose one
1 point

Recovery begins on a system containing both liquid and vapor refrigerant. Which approach generally speeds recovery while still allowing the technician to complete the recovery procedure?

  1. A

    Recover the available liquid refrigerant first, then continue as required.

  2. B

    Recover vapor only and leave all liquid in the system.

  3. C

    Open the system to the atmosphere to speed the process.

  4. D

    Heat the recovery cylinder with a torch.

19
Choose one
1 point

A technician is evacuating a chiller that contains water in its tubes. Why should the technician circulate or remove the water during evacuation?

  1. A

    It helps prevent water from freezing in the tubes as pressure and temperature fall.

  2. B

    It increases the refrigerant's ozone-depletion potential.

  3. C

    It forces refrigerant into the purge unit.

  4. D

    It raises the vacuum pump's oil level.

20
Choose one
1 point

A low-pressure chiller's purge unit begins operating much more frequently than usual. What problem should the technician consider?

  1. A

    Air or other noncondensables may be entering the system, potentially through a leak.

  2. B

    The system must contain too much oil.

  3. C

    The recovery cylinder is underfilled.

  4. D

    The water circuit is necessarily operating normally.