01
Front

What qualifies as a small appliance under Type I?

Back

A small appliance is factory-manufactured, charged, and hermetically sealed, with 5 pounds (2.27 kg) or less of refrigerant.

02
Front

When is Section 608 certification generally required for small-appliance work?

Back

A technician who may disturb the refrigerant circuit generally must hold the appropriate Section 608 certification.

03
Front

Does the disposal-related certification exemption eliminate the duty to recover refrigerant?

Back

EPA exempts small appliances from the certification requirement for refrigerant recovery when preparing them for disposal, but refrigerant still must be properly recovered.

04
Front

What recovery level applies when recovery equipment was made before November 15, 1993?

Back

Recover at least 80% of the refrigerant, or use the alternative evacuation option of 4 inches of mercury vacuum.

05
Front

What does the 4-inch mercury vacuum option measure?

Back

It is a vacuum reading relative to atmospheric pressure, not an absolute pressure reading.

06
Front

How does self-contained recovery equipment remove refrigerant?

Back

Self-contained, or active, equipment uses its own compressor or another means to remove refrigerant; it does not rely on the appliance compressor.

07
Front

What should you do with a working compressor during passive recovery?

Back

Operate the compressor when using system-dependent recovery equipment on an appliance with a working compressor.

08
Front

How should you identify a refrigerant before connecting recovery equipment?

Back

Check the appliance label and service information before connecting equipment. Pressure–temperature comparisons can help diagnose a discrepancy, but are not a substitute for proper identification.

09
Front

How can technicians prevent cross-contamination and refrigerant emissions?

Back

Use compatible equipment and containers, do not mix refrigerants in a recovery container, and do not knowingly vent refrigerant during service; recover it instead.

10
Front

What must you never do to a hermetic compressor under vacuum?

Back

Never energize a hermetic compressor while it is under vacuum.

11
Front

What recovery level applies to post-November 15, 1993 equipment with a functioning compressor?

Back

Recover at least 90% of the refrigerant, or evacuate the appliance to 4 inches of mercury vacuum.

12
Front

What recovery level applies to post-November 15, 1993 equipment with a nonfunctioning compressor?

Back

Recover at least 80% of the refrigerant, or evacuate the appliance to 4 inches of mercury vacuum.