Timedora

Solving Energy-Balance Problems

A practical method for setting up, solving, and checking energy balances, with a worked turbine example.

Set Up and Check the Balance

Start with the boundary and sign convention

Before writing an energy balance, decide what the system is: identify the device or matter inside the boundary, then mark every inlet and outlet. This determines which transfers to include. A closed-system balance applies when no mass crosses the boundary. For a , mass can flow across it, so the balance must account for energy carried in and out by that mass. That flow-carried energy is not heat or shaft work.

For the convention used here, heat into the system and work out of it are positive. In the closed-system form, this is expressed as ΔE=Q−W\Delta E=Q-W. Label transfers as positive or negative under the chosen convention before inserting numbers. With this convention, work done on a is negative work-out, so it increases the system’s energy.

Make assumptions explicit and check units

Simplifying assumptions reduce the balance, but they must be stated and justified. Examples include , adiabatic operation (no heat transfer), negligible kinetic- or potential-energy changes, and no accumulation. In particular, does not mean no energy transfer: it means no energy accumulates in the , even though energy can continuously enter and leave.

Keep properties and flow rates in compatible units. For example, (kg/s)(kJ/kg)=kJ/s=kW(\mathrm{kg/s})(\mathrm{kJ/kg})=\mathrm{kJ/s}=\mathrm{kW}. Convert terms before adding them; total energy in kJ cannot be added directly to a power in kW without accounting for a time interval or converting consistently.

After solving, interpret the sign rather than reporting a number alone. A positive work-out result means the device produces work under this convention. A negative result means work must be supplied to the device. Finally, check that omitted terms really are negligible and that every included transfer matches the boundary you defined.

Worked Example: Turbine Power and

Reduce the balance using the stated conditions

A steady, adiabatic turbine receives steam at m˙=2.0 kg/s\dot m=2.0\ \mathrm{kg/s}. The inlet and outlet enthalpies are h1=3200 kJ/kgh_1=3200\ \mathrm{kJ/kg} and h2=2600 kJ/kgh_2=2600\ \mathrm{kJ/kg}. Changes in kinetic and potential energy are negligible. For the same inlet state and outlet pressure, an ideal isentropic expansion would produce 700 kJ/kg700\ \mathrm{kJ/kg} of work.

The boundary surrounds the turbine, so this is a control-volume balance: steam flows in and out. Under the stated assumptions, there is no heat transfer, no accumulation, and no significant kinetic- or potential-energy change. The balance therefore reduces to work output from the enthalpy drop:

W˙out=m˙(h1−h2)=(2.0 kg/s)(3200−2600 kJ/kg)=(2.0)(600) kJ/s=1200 kW.\dot W_{out}=\dot m(h_1-h_2) =(2.0\ \mathrm{kg/s})(3200-2600\ \mathrm{kJ/kg}) =(2.0)(600)\ \mathrm{kJ/s}=1200\ \mathrm{kW}.

The turbine delivers 1200 kW of shaft power. The units check is important: kg/s\mathrm{kg/s} multiplied by kJ/kg\mathrm{kJ/kg} gives kJ/s\mathrm{kJ/s}, which is kW\mathrm{kW}. This is a positive work-out result under the selected sign convention.

Compare actual and ideal work

The actual work output per unit mass is the enthalpy drop, 600 kJ/kg600\ \mathrm{kJ/kg}. Divide it by the specified ideal for the same inlet state and outlet pressure:

ηt=h1−h2wisentropic=600 kJ/kg700 kJ/kg=0.857≈85.7%.\eta_t=\frac{h_1-h_2}{w_{isentropic}} =\frac{600\ \mathrm{kJ/kg}}{700\ \mathrm{kJ/kg}} =0.857\approx85.7\%.

This compares actual output with a chosen ideal output; it is not a statement that energy has been destroyed. The first-law balance tracks energy transfers and storage, while evaluates output relative to a stated basis. If the turbine were not adiabatic, heat transfer would need to appear in the balance, and the comparison would need to be reconsidered rather than applying this simplified result unchanged.

  • : The chosen matter or device whose energy is being tracked.